(2) Lux adjustment
The LUX adjustment sets the brightness level threshold that will activate the motion
sensor. The Lux control can be adjusted between T (always triggered regardless of
light level) and the moon symbol (triggered on only during hours of darkness). The
adjustable Lux range is about 30 - 200 Lux.
\LIJX
Always ON
During hours or darkness
1.
To set the lux level, turn the Time-off knob to "T" for maximum response.
2.
Turn the LUX control knob to the "moon" (dusk) position.
3.
Wait until the ambient light level reaches the level of darkness at which you wish the
floodlight to activate.
4.
Slowly rotate the Lux knob anti-clockwise while keep creating motion during the
process until the floodlight turns on. At this position the light will operate at
approximately the same level of darkness each evening.
5.
Set the Time-off knob back to the desired preset time.
6.
When completed, tighten the two Allen screws on the side of the floodlight body to
secure its position
Note: When connected to a Z-Wave controller, the manual settings will be overwritten by
the settings through the Z-Wave controller.
Operation
Z-Wave Group
The unit supports either one of two Z-Wave Association Groups:
Group 1: Association with 1 Controller node.
Group 2: Association with 4 nodes (i.e. end devices such as smart plugs and other lighting
controllers). This allows the PIR detector on the unit to transfer commands directly to other
Z-Wave end devices without the participation of the controller. This has the effect that when
its detector triggers, all devices associated with unit will be operated.
Table below are control commands that can be sent from the controller. Refer to
Programming section for details on sending these commands.
mman s rom ontro er
omman s
Turn on Floodli ht
Switch Bina Set n/ Basic et n
urn o
loodlight
Switch Binary Set
I Basic
t
et mer
Set ux leve
ead ux leve
Note: The floodlight will revert back to its own
self control onl after this command is sent
onfi uration settin s, Parameter
Confi uration settin s, Parameter
ultileve sensor: xo
Table below shows the alerts sent by the unit whenever an
event occurs. Refer to
Programming section for details of these notifications.