Installation & Wiring instructions

1.  Use  the  mounting bracket  to  mark the  position of  the

mounting holes

2.  Dnll the holes and insert suitable wall plugs

3.  Fix the mounting bracket to the wall using suitable 

screws.

Wiring instructions

WARNING:  Isolate  the mains  power supply to prevent electrical shock.

4.

It is  recommended  to add  an intemal single  pole wall switch to allow 

easy  control of the

AC POVER

N

N

5.

Connect  the mains  power supply to the pre-wired cable provided with the fitting as

shown above.  If the connection is made outdoors a suitable waterproof IP box must be

used to make the connections.

Follow exactly  the wire colors as  below:

-  BROWN  (Live)  wire to the mains live connection via a wall switch

-  BLUE  (Neutral) wire to the mains neutral connection.

- GREEN/YELLOW  wire to a suitable earth point. The  unit must be earthed.

Note: Do  not remove the pre-wired supply cable. This  will invalidate the warranty.

4

Содержание EH403

Страница 1: ...el and the timer can be set throughknobs on thedevice itself When added intoa Z Wave network EH403 communicatesdirectlywithotherend devices such as smart plugs orto reportdirectlytoa Z Wave controller usually a gateway It alerts the controllerwhen motionis detectedand throughZ Wave commands the controllercan remotely turn on offthe floodlightat any time and be able to configure its lux level and t...

Страница 2: ... the cable plug to the wall socket to powerup the unit WARNING be careful not to touch any exposed wire contactsto preventelectrical shock 4 The Link LED will start to blink slowly with2 second on 2 second off for2 minutes which shows the unitdoes notbe paired 5 Within 30 seconds put the Z Wave Controller into inclusion mode 6 The Inclusion process should be completed when the Link LED stops blink...

Страница 3: ... directly towards tho detector PIR less sensitive PIR moresensitive For the best results mountthe floodlightontonormalbrickwork1 8 20m above the ground At this height the unitWilldetect movement withinits 110degrees fan shaped detectionpatternup to8m dependingon adjustment 2 Topview 4 Side view SAFETY PRECAUTION DO NOT install when it is raining Isolatethe powersupply beforeInstallation Ensure tha...

Страница 4: ... wall switch to allow easy controlof the AC POVER N N 5 Connect the mains power supply to the pre wiredcable providedwiththe fittingas shown above If the connection is made outdoorsa suitablewaterproofIP box must be used tomake theconnections Follow exactly the wire colors as below BROWN Live wire to the mains live connection via a wall switch BLUE Neutral wire to the mains neutralconnection GREEN...

Страница 5: ...off before movingagain to test 2 If necessary tiltthe floodlightto achieve desired result The floodlightmay be tilted downwards by up to 300to light the area directly under it Tilting by more than 300may cause issues with the lux sensor as light reflectedback from the area under the floodlight may switch the lux sensor to daylight mode hence turningthe floodlightoff 3 When you are satisfied with t...

Страница 6: ...ected to a Z Wave controller the manualsettingswillbe overwrittenby the settings throughtheZ Wave controller Operation Z Wave Group The unit supports either one of twoZ Wave Association Groups Group 1 Association with 1 Controller node Group 2 Association with4 nodes i e end devices such as smartplugs and otherlighting controllers This allows the PIR detectoron the unittotransfer commands directly...

Страница 7: ...iggerOFF Groupf Switch BinaryRoport Group f Bastc Set Off Group2 Z Wave commands notrfication Remark otircation irst owor p roup evtce eset oca oti cation rou Installer Icon User Icon Sensor NotificationDevice Sensor NotificationDevice T e Home Secunt Home Securit Association Command Class Group Max Node 1 2 4 Version Protocol Library Protocol Version Manufacturer Manufacturer ID ox0060 AGI Associ...

Страница 8: ...Parameter Size 3 2 Range 30 200 Range Default 50 Default 0 1440 minutes 0 0ff 4 MultilevelSensor Reads back the lux level measured Tolerance of 30 lux Level above 250 willbe read back as 250 Sensor Type Precision Scale ox03 1 CommandClasses Size 2 The modulesupports Command Classes including COMMANDCLASS ZWAVEPLUS INFO V2 COMMAND CLASS ASSOCIATION vr COMMAND CLASS ASSOCIATION GRP INFO COMMAND CLAS...

Страница 9: ...teps involved when adding or removing the unitfrom the Z Wave network Action Status No node ID Auto Inclusion Manual Inclusion Exclusion FactoryReset This procedure should only be used when the controller is inoperable Description The Z Wave Controllerdoes notallocate a node ID to the unit The power is applied for the first timeand no node ID has been stored in the module or after executingreset 1...

Отзывы: