background image

Ú

  The ID code setting is stored in non-volatile memory and is not lost during 

power failures.    It can be cleared by proceeding with ID code clearance as 
indicated below in ID code clearing section. 

 

Ú

 

Up to 12 ID codes can be learned.    The Module’s LED will flash rapidly as 
rejection if the 13

th

 ID code is entered. 

 

Clearing the ID Code 
 

(1)    Press the button for 3 seconds until the LED flashes rapidly. A 30-second 

countdown will start. 

 
(2)    Press the button again more than 6 seconds within 30-second countdown, 

the preset ID code will be cleared. 

 

Operation 

 
Simply press the On/Off knob.  The red indicator LED will turn On and the 
incandescent lamp screwed into the Module will also turn on, while pressing the 
knob again will turn off the incandescent lamp and its LED will be off. 
 

Troubleshooting 
 

Symptom 

Cause of Failure 

Recommendation 

The module not 
working and LED 
off 

1.  Poor connection       

between lamp cap of   
mounted ceiling and 
lamp cap of the lamp 
holder 

2.  The module break 

down 

1.  Check if the lamp cap of      

mounted ceiling fits well 
into the module 

2.    Don’t open up the module and send 

it for repair 

The module’s LED 
working, but the 
connected light bulb 
not working 
 

1.  Light bulb has burnt 

out 

2.  Poor connection  or 

improper assembly 
between lamp cap of 
the light bulb and lamp 
holder of the module 

3.  The module break 

down 

1.  Replace a new bulb 
2.    The light bulb has screwed tightly to

the lamp holder of the module 

3.    Don’t open up the module and send 

it for repair 

 

Compatibility 

The following transceivers (sold separately) can control THIS module: 

923.00 MHz/868.30MHz 

     

           

             

               

     

Transmitter   USB Dongle  Flood Detector  IR Beam Detector   Temperature &     Illumination 

                                                                                                                      Humidity Detector        Sensor         

 (AC124)      (SA804)      (ST802)         (ST803)           (ST804)          (ST805)     

IMPORTANT! To avoid poor compatibility with devices of other brands, purchase 
only Everspring UNet devices to ensure best compatibility is strongly 
recommended.

 

 
Specification 

 

AN144-1 120VAC/60Hz 

E26 

AN144-2 230VAC/50Hz 

E27 

Operating Voltage / 
Type of Lamp Cap 

AN144-4 230VAC/50Hz 

B22 

Maximum Load 

100 Watts incandescent, 27 Watts energy saving bulb 

Operating Temperature 

0

°

C~40

°

Operating Humidity Range

85%RH 

Receiving Range 

30 meters min. line of sight 

Frequency Range 

923.00MHz or 868.30MHz 

** Specifications are subject to change and improvement without notice.

             

 

 

 

Federal Communication Commission Interference Statement 

This equipment has been tested and found to comply with the limits for a Class 
B digital device, pursuant to Part 15 of the FCC Rules.  These limits are 
designed to provide reasonable protection against harmful interference in a 
residential installation.    This equipment generates, uses and can radiate radio 
frequency energy and, if not installed and used in accordance with the 
instructions, may cause harmful interference to radio communications.  
However, there is no guarantee that interference will not occur in a particular 
installation.  If this equipment does cause harmful interference to radio or 

 

Confidential Information of Everspring Industry Co. Ltd

.

 

Отзывы: