background image

AN144 

SCREW-IN ON/OFF MODULE   

 
The AN144 Screw-in On/Off Module is a transceiver which belongs to the 
member of UNet series and is fully compatible with any UNet enabled devices. 
The connected light bulb can either be turned On/Off remotely by receiving RF 
signal emitted from compatible UNet devices or manual override. 
 

Initial Power Up & Installation 

 

As soon as the light bulb is screwed into the lamp holder, the LED on the Module 
will be flashing slowly.    This implies that the Module does not memorize any ID 
code and cannot work with UNet enabled devices.  However, pressing the 
On/Off knob will control directly the On/Off status of the connected incandescent 
lamp without using the Wireless Controller. 
 
(1)    Turn off the wall switch on the wall or mains power supply. 
 
(2)    There are three types of lamp caps – B22, E26, E27.    Choose whichever 

suits you most. 

 
(3)  The Module is designed for ceiling mounting. Fit the Module into the 

existing lamp cap. 

     
(4)    Place the light bulb into the lamp holder (Fig. 1). 
 

Note

: To prevent the Module from being damaged by heat, please… 

 

Ú

 

Don’t screw Module in an airtight environment/lamp stand. 

 

Ú

 

Don’t screw tungsten bulb into the Module.   

 
 
 
 
 
 
 
 
 
 

 
 

Fig. 1

 

Learning the ID Code 

 
(1)  In the front cover, there is an On/Off knob with LED indicator (Fig. 2).   

 
 
 
 
 
 
 
 
 
 

Fig. 2 

 

Note:

 This On/Off knob serves as a gateway to learn and clear the ID code. 

 

(2)  Keep pressing the button for 3 seconds until the LED flashes rapidly. A 

30-second countdown will start. The Module is about to learn the ID code. 

 
(3)  Using the Remote Controller of UNet

 

enabled device to emit the ID code to 

the Module, press and hold the “Off” button on the Remote Controller more 
than 3 seconds, so as to emit the ID code to the Module. 

 
(4)  If the Module learns the ID code properly, the LED indication will be on for 1 

second then turn off. 

 
(5)  When the LED flashes rapidly for 3 times, it is ascribed to the following 

two conditions: 

i. 

The Module failed to learn the ID code. 

ii. 

After entering 30-second ID code learning mode, press the 
button again to exit the ID code learning mode. 

 

Note: 

Ú

  At the step (2), if you happen to press the On/Off button for less than 3 

seconds, the Module will either turn to “On” or “Off” status depending on the 
last status of the On/Off button, for instance…… 

 

a.  If it was toggled as “Off”, the Module will turn to “On” status. 
b.  If it was toggled as “On”, the Module will turn to “Off” status. 
 

B22 lamp cap

E26/E27 lamp cap

ON/OFF KNOB
LED INDICATOR

B22 lamp cap

E26/E27 lamp cap

LIGHT BULB

 

Confidential Information of Everspring Industry Co. Ltd

.

 

Отзывы: