24
GB
9� FUNCTIONS
9�1� Tare function
See Figure 8
Item
Description
A
Weight with accessories
B
Tare completed
C
Lift a load. = Net weight
D
1 pulse Net Weight <> Gross weight
Note: When the tare function is enabled, a load reduction can optionally switch the display to negative.
9�2� Peak load function
See Figure 9
Item
Description
A
Current measurement
B
Activating the Peak Load function
C
The peak value of the measurement remains displayed
D
Disabling the Peak Load function
Notes:
• The tare function is available in Peak Load mode.
• In peak load mode, the reading frequency shifts from 3
Hz to 32 Hz.
9�3� Changing units
See Figure 10
Press and maintain T3 to scroll through the units, releasing T3 to select the unit.
9�4� Stop
See Figure 11
Item
Description
A
Current measurement
B
Complete shutdown of the device
Note: If it is not requested, the unit will automatically turn off after 20
minutes.
10� BATTERY REPLACEMENT
The battery indicator flashes when they are discharged. Then proceed to their replacement.
• Using a Phillips screwdriver, remove the battery box cover.
• Replace the 2
1.5 V batteries
“AAA” with new batteries, checking polarity.
• Replace the battery cover and tighten the screws so that the cover is flush with the edge of the battery case.
Heben • Sichern • Fördern • Verpacken