![Evers BPT-L19 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/evers/bpt-l19/bpt-l19_service-manual_2444904015.webp)
3.3.7 System error process
No.
System error
System response
Signalling
Rectification
E50
Abort sealing: Trigger pulled (S4:0)
Cancel sealing process. (E2) Error Code, oran-
ge backlight,
symbol pulsating
beep tone, average
Incorrect sealing.
– Repeat strapping
– Replace operating
lever switch
E53
Timeout sealing mechanism (S3)
– Mechanical components jammed
– Cam switch / wiring defective
Cancel sealing process. (E2) Error Code, red
backlight,
symbol pulsating
beep tone, long
Incorrect sealing.
– Repeat strapping
– Clean mechanical
components
– Check/replace
home switch S3
E54
Timeout sealing process (End position not
found)
– Mechanical components jammed
– An attempt was made to seal a strap
that had already been sealed.
Cancel welding process. (E2) Error Code, red
backlight,
symbol pulsating
beep tone, long
Incorrect sealing.
– Repeat strapping
– Clean mechanical
components
– Multiple sealings
are not permitted.
E55
Performance limitation [AUTO]
Cancel tensioning pro-
cess.
(E1) Error Code, oran-
ge backlight,
symbol &
pulsating beep tone,
average
– Repeat auto
tensioning.
E56
Timeout tensioning process [AUTO]
Cancel tensioning pro-
cess.
(E1) Error Code, oran-
ge backlight, pulsating
beep tone, average
– Repeat auto
tensioning.
E57
Strap torn or slipped
Cancel tensioning
process
idle state, BE = 0
(E1) Error Code, oran-
ge backlight, pulsating
beep tone, average.
Symbol flashes
– Reduce tensioning
force
– Insert the strap
again.
– Clean or replace
the tensioning
wheel
E60
Crimp mechanism not initialised. Crimp
mechanism not in home position
Cancellation of the
switch-on process. Tool
tries to find the home
position
(E2) Error Code, oran-
ge backligh,
Symbol
pulsating beep tone,
average
– Crimp mechanism
initialise (Homing)
E61
Timeout Initialisation of the crimping me-
chanism (homing)
Abort initialisation crimp
mechanism
(E2) Error Code, red
backligh,
Symbol
pulsating beep tone,
long
In case of recurrence:
– Home switch S3
mech. actuation
check
– Replace Switch S3
– Engine diagnosis
carry out
E62
Crimp current has exceeded higher war-
ning level
(E1) Error Code, oran-
ge backligh,
Symbol
pulsating beep tone,
average
Crimping may not be
correct:
– Check/clean me-
chanics
– Check wear parts
E63
Crimp current has not exceed lower
warning level
(E1) Error Code, oran-
ge backligh,
pulsating beep tone,
average
Crimping may not be
correct
E64
Crimping current has exceeded maximum
permissible current
Abbruch Crimpvorgang
(E2) Error Code, red
backligh,
Symbol
pulsating beep tone,
average
Crimping not correct
→ Repeat the strap
-
ping process
– Check/clean me-
chanics
– Check wear parts
Evers GmbH Graf-Zeppelin-Str. 10 46149 Oberhausen T49 208 99475-0 T49 208 99475-31 [email protected] eversgmbh.de