background image

Flushing and Draining:

To flush or to drain the Everlast™ Series 2000 water heater, power must be 

turned off and then turn off the cold water supply to the water heater.  The 

lever on the pressure and temperature relief valve should be opened but 

care should be taken so the lever does not snap back as it could damage the 

valve seat.  The pressure in the water heater will be released when the lever 

is opened.
The union at the cold water inlet to the water heater should be undone and a 

hose should be attached to the water heater side of the union. The other end 

of the hose should go to a drain.
Installations including a drain cock, as shown in inlet piping schedule, are 

recommended as this allows for draining and for periodic flushing of the 

water heater without piping disconnection at unions, and without the need for 

rechecking for leaks after reconnection.
Opening the pressure and temperature relief valve allows air into the water 

heater and for the water to drain. Following complete draining of the water 

heater, the closest hot water taps may be opened fully and the pressure and 

temperature relief valve closed with care. The cold water inlet stop valve 

is now opened fully and the water heater may be filled with cold water and 

flushed through to ensure the cylinder contains no sediment and is clean. 

Finally the closest hot taps are closed and power may be turned on again 

tothe completely filled water heater.

4          Warranty Conditions

1. 

The system must be installed by a licensed plumber and/or  

 

electrician in accordance with Everlast™ installation  

  

instructions; and all relevant statutory and local requirements of

 

the State or Territory in which the system is installed.

 

2.    The Everlast™ Series 2000 water heater must be operated and 

 

maintained in accordance with instructions supplied by  

 Everlast™.

 

3.  

This warranty only applies to the water heater product and does not

 

apply to any additional electrical and/or plumbing parts  

 

supplied by the installer.

 

4.  

The system is covered for the indicated period from the date of the

 

original purchase. Should a part of the complete water  

 

heater component be replaced during this period, only the  

 

balance of the original warranty will continue to remain effective.

 

Proof of purchase is required.

 

EVERLAST MANUAL 16pp.indd   11

9/07/10   11:02 AM

Содержание series 2000

Страница 1: ...EVERLAST MANUAL 15 8 2008 indd 1 20 8 08 10 35 05 AM EVERLAST MANUAL 16pp indd 1 9 07 10 11 02 AM...

Страница 2: ...ncluding Marine Grade stainless steel cylinder Control of thermal stratification Dual Positive Domed Cylinder resulting in optimum location of element s water supply and delivery and flushing through...

Страница 3: ...osphere and suitably located to not become blocked Should a continuous discharge occur we recommend that you consult your licensed plumber as this may indicate a defective P T valve defective thermost...

Страница 4: ...ustible Material It is recommended to not place combustible material on or adjacent to the water heater Internal Installation Safe Tray For internal indoor installations a safe tray is recommended in...

Страница 5: ...00 water heater is designed to ensure total drainage for flushing if required It is recommended that a drain cock be installed on the cold water inlet pipe adjacent to the heater to facilitate flushin...

Страница 6: ...a and 99 C The Expansion Control Valve if required by some Authorities is set to 700 kPa max AS MAINS pressure COMMONLY exceeds 500 kPa fit A Pressure Limiting Valve set to 500 kPa INSTALLATION DIAGRA...

Страница 7: ...RMAL THERMOSTAT MAXIMUM THERRMOSTAT THERMAL CUT OUT THERMOSTATS MODEL NUMBER SETTING SETTING NON SOLAR APPLICATIONS Top Thermostat ST2207233 Fixed at 60 C Fixed at 60 C 88 C Bottom Thermostat ST120113...

Страница 8: ...the Circuit Continuity Test across the element which should indicate an element resistance of approx 11 13 Ohms ALWAYS carry out circuit continuity tests with no circuit load as the element resistanc...

Страница 9: ...rmostat 5 will be OPEN CIRCUIT with CLOSED CIRCUIT between 1 and 4 until bottom element has heated water above 60 C Above 60 C 1 2 is now CLOSED CIRCUIT AND 1 4 is now OPEN CIRCUIT Therefore Wiring Te...

Страница 10: ...cturer The thermostat model numbers are noted on the Wiring Plans Figures 3 4 DANGER The operation of the over temperature safety cut out indicates a possibly dangerous situation Do not reset the ther...

Страница 11: ...aps may be opened fully and the pressure and temperature relief valve closed with care The cold water inlet stop valve is now opened fully and the water heater may be filled with cold water and flushe...

Страница 12: ...he following warranty exclusions may cause the system warranty to become void This may incur a service charge and cost for parts should they be necessary 1 Where service is required to reconnect the w...

Страница 13: ...ect of the product which the purchaser has under the Trade Practices Act Commonwealth 1975 and similar State or Territory Laws Warranty Cover Single Domestic Single Multi Application Commercial Applic...

Страница 14: ...________________________________________________________________ Town Suburb__________________________State____________Postcode ___________ Electrician____________________________________Licence No _...

Страница 15: ...______________ Installed by Plumber____________________________________ Licence No _______________ Address _____________________________________________________________ Town Suburb____________________...

Страница 16: ...Printed May 2012 Product Code number 44953 EVERLAST MANUAL 16pp indd 16 9 07 10 11 02 AM...

Отзывы: