background image

5.    The system is installed in a domestic household. (for 10 year

 

Warranty period).

6.   Should this system be installed in a regional location where  

 

regular flushing is required due to sediment build-up, then the  

 

drain cock for flushing must be fitted at the time of installation.  If 

 

in doubt consult your plumber.

 

7.   Where the heater is installed outside the boundaries of a Capital  

 

Cities Metropolitan area i.e. those areas on STD, the cost of 

 

transport, insurance and travelling between the nearest 

 

Everlast™ accredited Service Agent’s premises will be charged 

 

to the owner.

8. 

EVERLAST ™ Hydro Systems is excluded to the extent allowable by

 

law from responsibility for any consequential loss including; injury to

 

persons, injury to property, economic loss, pain and suffering or legal

 

or other damages flowing from any manufacturing fault/defect.

 

Warranty Exclusions

The following warranty exclusions may cause the system warranty to become 

void.  This may incur a service charge and cost for parts should they be 

necessary.
1.   Where service is required to reconnect the water heater  

 

operation due to problems related with abnormal water supply  

 

(i.e. high water pressure), faulty plumbing and/or electrical  

 

wiring, or major variations in electrical energy supply.

 

2.   Where the system fails due to misuse, accidental damage,  

 

flood, acts of God, incorrect installation or unlicensed service  

 

repair work attempts.

 

3.   Where system service is required due to the non-conformance  

 

with this warranty’s recommended maintenance in certain water 

 

quality conditions (refer installation to facilitate flushing, Sec. 2 

 above).

 

4.   Claims for damage to walls foundations (outside), furnishings  

 

(inside), roofs or other losses, directly or indirectly due to  

 

leakage from the water heater.

 

5.   Damage or breakage is not covered by this warranty, and should 

 

be added separately to your general household insurance policy.

EVERLAST MANUAL 16pp.indd   12

9/07/10   11:02 AM

Содержание series 2000

Страница 1: ...EVERLAST MANUAL 15 8 2008 indd 1 20 8 08 10 35 05 AM EVERLAST MANUAL 16pp indd 1 9 07 10 11 02 AM...

Страница 2: ...ncluding Marine Grade stainless steel cylinder Control of thermal stratification Dual Positive Domed Cylinder resulting in optimum location of element s water supply and delivery and flushing through...

Страница 3: ...osphere and suitably located to not become blocked Should a continuous discharge occur we recommend that you consult your licensed plumber as this may indicate a defective P T valve defective thermost...

Страница 4: ...ustible Material It is recommended to not place combustible material on or adjacent to the water heater Internal Installation Safe Tray For internal indoor installations a safe tray is recommended in...

Страница 5: ...00 water heater is designed to ensure total drainage for flushing if required It is recommended that a drain cock be installed on the cold water inlet pipe adjacent to the heater to facilitate flushin...

Страница 6: ...a and 99 C The Expansion Control Valve if required by some Authorities is set to 700 kPa max AS MAINS pressure COMMONLY exceeds 500 kPa fit A Pressure Limiting Valve set to 500 kPa INSTALLATION DIAGRA...

Страница 7: ...RMAL THERMOSTAT MAXIMUM THERRMOSTAT THERMAL CUT OUT THERMOSTATS MODEL NUMBER SETTING SETTING NON SOLAR APPLICATIONS Top Thermostat ST2207233 Fixed at 60 C Fixed at 60 C 88 C Bottom Thermostat ST120113...

Страница 8: ...the Circuit Continuity Test across the element which should indicate an element resistance of approx 11 13 Ohms ALWAYS carry out circuit continuity tests with no circuit load as the element resistanc...

Страница 9: ...rmostat 5 will be OPEN CIRCUIT with CLOSED CIRCUIT between 1 and 4 until bottom element has heated water above 60 C Above 60 C 1 2 is now CLOSED CIRCUIT AND 1 4 is now OPEN CIRCUIT Therefore Wiring Te...

Страница 10: ...cturer The thermostat model numbers are noted on the Wiring Plans Figures 3 4 DANGER The operation of the over temperature safety cut out indicates a possibly dangerous situation Do not reset the ther...

Страница 11: ...aps may be opened fully and the pressure and temperature relief valve closed with care The cold water inlet stop valve is now opened fully and the water heater may be filled with cold water and flushe...

Страница 12: ...he following warranty exclusions may cause the system warranty to become void This may incur a service charge and cost for parts should they be necessary 1 Where service is required to reconnect the w...

Страница 13: ...ect of the product which the purchaser has under the Trade Practices Act Commonwealth 1975 and similar State or Territory Laws Warranty Cover Single Domestic Single Multi Application Commercial Applic...

Страница 14: ...________________________________________________________________ Town Suburb__________________________State____________Postcode ___________ Electrician____________________________________Licence No _...

Страница 15: ...______________ Installed by Plumber____________________________________ Licence No _______________ Address _____________________________________________________________ Town Suburb____________________...

Страница 16: ...Printed May 2012 Product Code number 44953 EVERLAST MANUAL 16pp indd 16 9 07 10 11 02 AM...

Отзывы: