SAFETY PRECAUTIONS 

WARNING

!   

 

Persons with pacemakers should not weld, cut or be in the welding area 

until they consult with their physician.  Some pacemakers are sensitive to EMF radiation 

and could severely malfunction while welding or while being in the vicinity of someone 

welding

Serious injury or death may occur!

 

 

Welding and plasma cutting processes generate electro-magnetic fields and radiation.  
While the effects of EMF radiation are not known, it is suspected that there may be 
some harm from long term exposure to electromagnetic fields.  Therefore, certain pre-
cautions should be taken to minimize exposure: 

 

 Lay welding leads and lines neatly away from the body.  

 

 Never coil cables around the body.   

 

 Secure cables with tape if necessary to keep from the body. 

 

 Keep all cables and leads on the same side the body.  

 

 Never stand between  cables or leads.   

 

 Keep as far away from the power source (welder) as possible while welding.  

 

 Never stand between the ground clamp and the torch.   

 

 Keep the ground clamp grounded as close to the weld or cut as possible.   

 
Welding and cutting processes pose certain inhalation risks.  Be sure to follow any 

guidelines from your chosen consumable and electrode suppliers regarding possible 
need for respiratory equipment while welding or cutting.  Always weld with adequate 
ventilation.  Never weld in closed rooms or confined spaces.  Fumes and gases re-
leased while welding or cutting may be poisonous.  Take precautions at all times.  
Any burning of the eyes, nose or throat are signs that you need to increase ventilation. 

 

Stop immediately and relocate work if necessary until adequate ventilation is ob-
tained.   

 

Stop work completely and seek medical help if irritation and discomfort persists. 

 

WARNING!  

Do not weld on galvanized steel, stainless steel, beryllium, titanium, cop-

per, cadmium, lead  or zinc without proper respiratory equipment and or ventilation. 
 

WARNING!  

This product when used for welding or cutting  produces fumes and gas-

es which contains chemicals known to the State of California to  cause birth defects 
and in some cases cancer.  (California Safety and Health Code 

§

25249.5  

et seq.) 

 

WARNING!

  Do not weld or cut around Chlorinated solvents or degreasing areas.  

Release of Phosgene gas can be deadly.  Consider all chemicals to have potential 
deadly results if welded on or near metal containing residual amounts of chemicals. 
 
Keep all cylinders upright and chained to a wall or appropriate holding pen.  Certain 
regulations regarding high pressure cylinders can be obtained from OSHA or local 
regulatory agency.  Consult also with your welding supply company in your area for 
further recommendations. The regulatory changes are frequent so keep informed. 
 

All cylinders have a potential explosion hazard.  When not in use, keep capped and 
closed. Store chained so that overturn is not likely.  Transporting cylinders incorrectly 
can lead to an explosion.  Do not attempt to adapt regulators to fit cylinders.  Do not 
use faulty regulators.  Do not allow cylinders to come into contact with work piece or 
work.  Do not weld or strike arcs on cylinders. Keep cylinders away from direct heat, 
flame and sparks. 

 

Содержание POWERARC 300ST

Страница 1: ...Setup and General Use Guide Rev 3 1 001229 16 Analog DC Stick DC TIG IGBT Inverter Welder CC SMAW IGBT 1 3 PHASE DC everlastwelders com 1 877 755 9353 329 Littlefield Ave South San Francisco CA 94080...

Страница 2: ...uct in this manual are subject to change without notice or up date of this manual This manual is intended to be a general guide and not intended to be exhaustive in its content regarding safety weldin...

Страница 3: ...nce technical support available through the main company headquarters available in your country For best service call the appropriate support line and follow up with an email particularly if off hours...

Страница 4: ...orums index php Main toll free number 1 877 755 WELD 9353 9am 5pm PST M F 11am 4pm PST Sat FAX 1 650 588 8817 Everlast Canada Everlast consumer satisfaction email sales everlastwelders ca Everlast Web...

Страница 5: ...unit Do not operate the unit until you have read this manual and you are thoroughly familiar with the safe operation of the unit If you feel you need more information please contact Everlast Support...

Страница 6: ...equip ment If no protection is available exclude them from the work area Even brief expo sure to the rays from the welding arc can damage unprotected eyes Always wear hearing protection because weldi...

Страница 7: ...y burning of the eyes nose or throat are signs that you need to increase ventilation Stop immediately and relocate work if necessary until adequate ventilation is ob tained Stop work completely and se...

Страница 8: ...ion Keep all combustible materials including rags and spare clothing away from area Keep all flammable fuels and liquids stored separately from work area Visually inspect work area when job is complet...

Страница 9: ...aluminum or magnesium Need longer welding cables or an extension cord The welding cables are held into the DINSE style connectors by set screws located under the connector cover and can be accessed by...

Страница 10: ...The hot start can blow through the metal if the setting is too high for the given thickness of the metal On thin metals use a lightly penetrating rod such as an E6013 and a low hot start setting Arc...

Страница 11: ...g Contact Everlast for an optional TIG package if desired or source one local ly at a nearby welding supply store 2 3 Handling and general maintenance Duty Cycle and Overcurrent Be careful to observe...

Страница 12: ...e of the two negative ports Most electrodes require reverse polarity To maintain reverse polarity also known as positive polarity or DCEP the work clamp should be engaged in one of the two negative po...

Страница 13: ...t is grounded by the main ground wire to the chassis an additional bonded ground may be necessary in some locations to comply with code Consult a locally licensed electrician concern ing the any requi...

Страница 14: ...AN AND LOCAL CODES BEFORE MODIFYING EXISTING CIRCUITS OR IN STALLING THE WELDER See page 20 for further details and explanation GAS INLET 1 220 V OR 3 220v IMPORTANT EVERLAST IS NOT RESPONSIBLE FOR DA...

Страница 15: ...NERAL SETUP AND OPERATION Section 2 6010 TORCH WORK 6010 NOTE Also suitable for use with E6011 and other electrodes with cellulose based flux such as E7010 PowerARC 300ST STICK E6010 WELDING CONFIGURA...

Страница 16: ...TE Use this configuration with most standard electrodes except ones with cellulose flux such as E6010 6011 PowerARC 300ST STANDARD WELDING CONFIGURATION IMPORTANT Most electrodes require DCEP Always c...

Страница 17: ...st flow A regula tor is still needed to regulate max flow To connect Everlast torches some adaptation or modification of the torch gas line will be needed as is the case with most gas valve torches to...

Страница 18: ...electrode diameter selection chart below to determine the ap proximate range of amps suitable for the rod size selected Consult the welding electrode manufac turer s recommendation for proper amperage...

Страница 19: ...rotate the torch into welding position 6 Poor starts and welding of the tungsten to the surface can be a result of a rapid double tap or quick bounce off the surface of the metal and back down This i...

Страница 20: ...od sticking Wet welding rods Too low of amperage Too high of amperage Use fresh rods Adjust amps Wrong polarity Hot start Arc force too low Welding rod is rapidly consumed Too small of welding rod Too...

Страница 21: ...Tong style Stick electrode holder 10ft cable with DINSE 50 style connector 1 Steel work clamp 10ft cable with DINSE 50 style connector 1 PowerARC 300ST DC Stick Inverter welder 1 Manual NOTE Kit cont...

Страница 22: ...s used for a dryer or range connection do not match up to the standard wire colors used in wiring a welder In three phase 4 wires are used with 3 hot wires again out of phase with each other are used...