77
RAW WATER SYSTEM
8.1 General
A raw water manifold located in the systems com-
partment bilge supplies seawater to the raw water
pumps. The intake for the manifold is equipped
with a ball valve that turns the raw water main
supply to the manifold on or off. Other ball valves
at each connection on the manifold enable the
operator to turn the water supply on or off for
each individual pump in the system. Always make
sure all ball valves are open before attempting to
operate any component of the raw water system.
Priming the System
Make sure the ball valves are open and the Raw
Water switch in the helm switch panel is on. Run
the pressure pump by turning on the raw water
washdown hose until all of the air is purged from
the system and then turn the hose off. Turn the
Livewell and baitwell pump switches to the ON
position and run the pumps until all of the air is
purged from the system and turn the pumps off.
The intake for the raw water manifold is equipped
with a scoop and ball valve. If a pump runs but
will not prime make sure the valve is open. If
the pump still won’t prime, it may be air locked.
Make sure the valve is open and run the boat at
or above 15 M.P.H. The water pressure from the
scoop will force the trapped air through the pump
and allow it to prime. If this procedure doesn’t
work, contact your Everglades dealer.
Closing the thru-hull valves before the boat is
hauled from the water will help to eliminate air
locks in raw water systems. The valves should
also be closed whenever you leave the boat in the
water unattended.
Notice:
It may be necessary to reprime the raw wa-
ter system if it is not used for an extended
period and at the time of launching.
8.2 Raw Water System Operation
A high pressure pump, controlled by a pressure
sensor, is activated by the Raw Water switch lo-
cated in the helm switch panel. When activated,
Chapter 8:
the pressure switch will automatically control the
pump that supplies the raw water hose connector.
As the pressure builds in the system, the pump
will shut off. When the system is in use and the
pressure drops, the pump will turn on. The water
pump is equipped with a strainer on the intake
side of the pump. The strainer should be checked
frequently and cleaned as necessary.
Whenever the boat is left unattended, the Raw
Water switch should be placed in the OFF position.
Raw Water Manifold, Livewell Pump, Baitwell Pump, Raw
Water Supply Pump Connection and Ball Valves
Raw Water and Fresh Water
Pressure Pumps and Sea Strainers
Содержание 355 CC
Страница 1: ...OWNER S MANUAL 2013 355 CC 355 CCX...
Страница 2: ...2 Revision 1 6 28 2012...
Страница 16: ...16 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Страница 22: ...22 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Страница 25: ...25 Operation...
Страница 38: ...38 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Страница 58: ...58 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Страница 76: ...76 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Страница 84: ...84 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Страница 88: ...88 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Страница 120: ...120 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Страница 127: ...127 SCHEMATICS Appendix A...
Страница 128: ...128 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Страница 133: ...133 MAINTENANCE LOG Appendix C Hours Date Dealer Service Repairs...
Страница 134: ...134 Maintenance Schedule and Log MAINTENANCE LOG Hours Date Dealer Service Repairs...
Страница 135: ...135 Maintenance Schedule and Log MAINTENANCE LOG Hours Date Dealer Service Repairs...
Страница 136: ...136 Maintenance Schedule and Log MAINTENANCE LOG Hours Date Dealer Service Repairs...
Страница 137: ...137 Appendix D BOATING ACCIDENT REPORT...
Страница 138: ...138 Boating Accident Report...
Страница 139: ...139 Boating Accident Report...
Страница 140: ...140 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Страница 142: ...142 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Страница 147: ...CAUSE AND SOLUTION...
Страница 148: ...Everglades Boats 544 Air Park Road Edgewater Florida 32132 All Channels Lead to Everglades Boats...