6.3 Detail-Setup
- 29 -
6.3.4 Sabotage:
Up to 3 different kinds of sabotage detections can be defined for each of the four
channels:
Video fail
When a video signal fails
– channel
is activated (see
Camera Tool Bar
),
no video signal has been applied to
the input
– the LED of the corres-
ponding channel flashes on the
front side of the device.
Videosignallevel
When this function is activated an
arithmetic reference value (for all
picture intensities within the defined
green area
prealarm3
) over 5 mi-
nutes will be calculated in order to
take account of slow luminance al-
teration, like twilight, common changing of weather conditions.
At the same time an arithmetic mean is registered over a short time of 10 seconds. In-
tensity changes by moving objects effects no alarm. A durable change like covering of
the camera objective or a lasting local variation in the camera picture causes a sabo-
tage alarm. In this case after 5-10 seconds an alarm is occurred.
The alarm threshold can be adjusted in 9 steps. In case of outdoor areas (short-term in-
tensity changes by sun or clouds) it is recommended to set the threshold to higher sig-
nal deviation.
Signalcharacteristic
By activating of this function a reference value will be initiated, however as an average
difference of the arithmetic mean. The calculation is done for the distribution of all inten-
sities within the camera picture. This feature is especially recommended for high-
contrast images, because sabotage by paint-spraying to the camera objective or distort-
ing of the camera-view effects a bad-focused and low-contrast image in the most cases.
The reference value is adapted dynamically. The notes for alarm activating and the
alarm threshold are
performed as described in „
Videosignallevel
‟.
A sabotage alarm can be indicated by energizing the sabotage relay and / or by sending
a serial sabotage string (definition for each channel; character entry and interface defini-
tion as described in „
Alarm
‟ on page 28).
The relay is energized as long as the sabotage is detected.
The transmission of the serial string starts with detecting a sabotage and
– setting „re-
peat‟ is activated – each second anew..