6.3 Detail-Setup
- 26 -
Relay functions:
Defines the settings of the channel- and global relay. The definitions
Retrigger
and
Re-
settime
are valid for both relays.
Retrigger relay:
If another alarm occurs during the time the relay is energized, the time
is automatically prolonged by the configured time.
Watchdog:
(De-) activate the watchdog function (relay is normal closed) of the channel
relay.
Resettime:
Defines the time the relay is in energized state. The maximum time is 120
seconds = 2 minutes
NOTE: The selected time is equal to the auto reset time for the LED display.
Global relay is NC:
If
activated, the watchdog function of the global relay is on.
.
..
Global Input:
The sensor is equipped with an external global input, which can be
considered by each channel separately :
Interpret contact:
If activated the contact state has to be according to the global con-
tact definition (see next parameter).
Contact is Normally Closed:
Subordinate channel can be linked to this input.
When the channel parameter „
Interpret contact‘
is activated, the channel only triggers if
a.)
the global input has been closed (checkbox „C
ontact is NC
‟ is active)
b.)
the global input is open (checkbox „
Contact is NC
‟ is not active).
6.3.2 Areaoptions:
All important parameters of the main area and the 3
prealarm areas are listed in this submenu. You can switch
the setting between the areas by clicking on the upper but-
tons.
..
Operationmode:
Defines the kind of operation mode (see description ‚
Area
parameters
„ on page 22).
..
Timer:
Defines the following timer:
Resettime:
Timer is started when the sensor area initiates an alarm.
After expiration the alarm of the sensor area is reset. This
includes: The internal linking (see
“
Logic
” on page 30) and
the transmitting of the serial alarm strings (
„Alarm OFF
strings‟, see page 28).
NOTE:
The
channel
relay
will
only
be
reset
after
expiration
of
the
relay energizing time set under “C
ameraoptions
”.