HD Off:
Figure 4-16 Alarm & Event Menu – Event - HD Off
Buzzer:
Check box to enable buzzer if the hard drive is turned off (disconnected) or becomes disabled
(cannot be detected by the system).
Email Notify:
Check box to enable email notification when HD is off. Email operation requires that valid
email settings have been entered in the Network Setting/Email setup screen.
Network Alarm:
Check box to send out a network alarm to client PC. (requires PowerCon software and
setting up Alarm Server in Network Setup menu)
Alarm Output:
This will transmit a signal through the alarm output relay. It can be set to either “
NONE
” (not
active), “
1
”(active) or “
2
” (active).
Output Type:
Output action when alarm is triggered.
Timeout: Alarm output lasts for the set time duration.
Permanent: Alarm will be continuously active until user presses “
Enter
” key.
Transparent: Alarm output remains active until event ends.
Trans+Timeout: Alarm output continues until event ends, then lasts for the set time duration.
Timeout Duration:
The amount of time the buzzer sounds when the HD is off. Duration selectable from 1
to 150
seconds.