8
○
○
○
○
8
RS485 socket:
For remote control via RS-485 keyboards and telemetry control for attached PTZ
devices
○
○
○
○
9
Main:
Main monitor for live and playback display and on-screen display.
○
○
○
○
10
Call:
Call monitor output. Spot monitor for full screen live display, sequence mode and alarm
camera switching.
○
○
○
○
11
Main VGA:
Main monitor - connect a VGA monitor to the VGA output connection. VGA resolution is
800x600.
○
○
○
○
12
Alarm In:
Connect up to 4 alarm inputs, selectable between N.O./N.C. contacts.
○
○
○
○
13
Video Out:
Looping Outputs - connect the camera video signals to other equipment as required.
○
○
○
○
14
Alarm Out:
N.C or N.O type alarm out (form “C”).
○
○
○
○
15
Audio Out:
Connect to the line level input of an audio amplifier
.