![EverFocus ECOR FHD 16F Скачать руководство пользователя страница 149](http://html.mh-extra.com/html/everfocus/ecor-fhd-16f/ecor-fhd-16f_user-manual_2443135149.webp)
ECOR FHD 4F / 8F / 16F Full HD DVR
141
Appendix C: Timing of Alarm Modes
Transparent Mode
Input Event
Alarm Duration
t
t
Event =
t
Reaction
t
Event
: Duration of alarm input source (motion, contact, system events...)
t
reaction
: Resulting duration for this alarm mode, related to event record, alarm outputs, OSD
message, buzzer
T Transparent Mode
t
Input Event
Alarm Duration
t
Duration
t
Reaction
t
Event
t
Event
: Duration of alarm input source (motion, contact, system events...)
t
Duration
: Alarm duration for timeout, defined in the event setup menus
t
reaction
: Resulting duration for this alarm mode, related to event record, alarm outputs, OSD
message, buzzer
Timeout Mode
Appendix
C