Volume 

EverAccess

 

Содержание EBC890

Страница 1: ...User Manual F Fl le ex x S Se er ri ie es s F Fi in ng ge er rp pr ri in nt t S Si in ng gl le e D Do oo or r C Co on nt tr ro ol ll le er r E EB BC C8 89 90 0 Volume 1 EverAccess...

Страница 2: ...2008 EverFocus Electronics Corp 1801 Highland Ave Duarte CA 91010 Phone 626 844 8888 Fax 626 844 8838 All rights reserved No part of the contents of this manual may be reproduced or transmitted in an...

Страница 3: ...s designed to operate in the temperature range 20 F 143 F Cleanse Power off the product before cleansing Do not use liquid cleaners or aerosol cleaners Use a damp cloth to clean it Maintenance Do not...

Страница 4: ...Components 9 Chapter 3 Hardware Installation 10 Mounting Fingerprint Controller 10 Connection to Door Lock 11 Connection to an Electric Strike 12 Connection to a Magnetic Lock 12 Connection to Reques...

Страница 5: ...nce 24 Way to Clean Fingerprint Module Surface 24 Chapter 7 Controller Functionality and Configuration 25 General Operation Guideline 25 Show Firmware Version 25 Enter System Configuration 26 Verify S...

Страница 6: ...g 38 Enter Door Setting Menu 38 Door Access Schedule Setting 38 Door Access Mode Setting 39 Open Time Setting 40 Set Door Hold Open Time 40 Set Door Control at Fire Alarm 41 Alarm Setting 41 Alarm Con...

Страница 7: ...Alarm 48 Chapter 8 Software Setup 50 Install the Software in the Control Computer 50 Setup the User Accounts for the Software 51 Configure the Controller and All Other Hardware 51 Configure the Holida...

Страница 8: ...ormat User password 6 digit System password 6 digit Alarm password 6 digit Alarm input 1 fire alarm 4 arm zone alarm inputs Alarm output 2 alarm outputs Communication ports RS232 or RS485 Band rate 96...

Страница 9: ...us access verification methods allow up to 12 authentication modes fingerprint alone fingerprint card fingerprint PIN fingerprint card PIN etc The EBC890 fingerprint controller features a fashion desi...

Страница 10: ...nstallation Support Wiegand 26 bit and 34 bit format Parts List Please be careful when you unpack the box due to the electronics devices inside Check and make sure that you have all the items listed b...

Страница 11: ...erminal definition label and frame mounting holes are located at the back panel of the fingerprint controller 1 Fingerprint module The auto on function will detect when a finger is approaching the opt...

Страница 12: ...s and index of the terminals are shown in the below figure Fig 2 Fingerprint Controller Terminals NO NO 8 9 7 10 11 12 Funct i on Funct i on 20 21 22 19 24 23 GND W gOut Dat a0 W gOut Dat a1 GND GND D...

Страница 13: ...TamperSwitchCOM Common pin of tamper switch relay output 11 GND GND 35 TamperSwitchNC Normally close pin of tamper switch relay output 12 DoorButton Request to exit button 36 Alarm1NO Normally open p...

Страница 14: ...talled and where It also is essential in determining the length of cable needed to connect readers to the controller A floor plan can be a blue print of the building a design or simply a drawing of th...

Страница 15: ...to exit device Step 1 Preparing for the Installation Obtain a floor plan Determine the hardware and location Determine the number of controller and modules and system architecture Step 2 Hardware Ins...

Страница 16: ...o control who can enter and who can exit It also allows the administrator to control when people can enter and exit Scenario 1 and 2 require one reader Scenario 3 requires two Each door module on the...

Страница 17: ...rnet interface is required 1 Each EverAccess controller can accommodate up to 8 card readers If the system to be installed requires more than 8 readers additional controllers are necessary These contr...

Страница 18: ...ch will lower the card sense range The fingerprint controller package contains a supporting frame to elevate the controller in order to make wire connections more convenient The installation is descri...

Страница 19: ...stening to push down secure the tamper switch Step 1 Step 2 Step 3 Step 4 Fig 6 Mount Fingerprint Controller Connection to Door Lock Electric strikes and magnetic locks are used to keep doors locked u...

Страница 20: ...s Terminal 44 is used for normally closed terminal N C locks The electrical door lock must have a separate power supply The power supply for the electrical door lock depends on the specification of th...

Страница 21: ...ied open time Connect the request to exit device to terminal 12 and 13 shown as the below figure Fig 9 Connecting REX to Controller Connection to Door Sensor Door sensor presents the door status i e i...

Страница 22: ...t setting Users can assign the corresponding relay status to the different events There are three terminals for each alarm output relay COM N O and N C The wiring depends on the alarm device Please re...

Страница 23: ...amper alarm will be triggered and the controller will energize the tamper switch relay output The NO COM and NC pin of the tamper switch relay are terminal 33 34 and 35 respectively Connect an alarm d...

Страница 24: ...e wired to the computer serial port as follows the RS232 TX terminal of the controller is linked to the RS232 RX of the serial port and the RS232 RX terminal is linked to the TX Note that 15 meter is...

Страница 25: ...roller to Desktop Reader via RS485 RS485 Bus Based Networking System Multiple EverAccess controllers can be connected to accommodate larger access control systems The controllers are connected via RS4...

Страница 26: ...mat as shown in the below figure Fig 20 The Daisy Chain Connection Controller to Controller Two common INCORRECT connection methods are displayed in Fig 21 as well EverAccess EverAccess SYS 7 8 9 6 5...

Страница 27: ...rs via RS485 Up to 127 controllers can be connected to each desktop reader via RS485 bus The correct RS485 connection method has been briefly introduced in the section entitled RS485 Bus Extension Her...

Страница 28: ...re that the installation PC is connected to the network that will be used to manage the controller Step 2 Connect the EA LAN1 to the local area network using a LAN cable and power up the EA LAN1 Step...

Страница 29: ...tage supply should be located no more than 2 meters 7 feet from the controller Also electric locks and alarm devices MUST be powered separately Reset Controller Before turning the power on please doub...

Страница 30: ...he operations must be performed in preparation before the first use 1 Set the date and time for the controller 2 Set the controller address 3 Configure door setting 4 Configure alarm settings 5 Config...

Страница 31: ...follow the below notes to capture a good fingerprint sample 1 Touch Fingerprint Module with the Pad of Your Finger Touch the controller with the pad of your finger instead of tip of finger Please see...

Страница 32: ...he dirt and dust on the controller doesn t affect fingerprint recognition Way to Clean Fingerprint Module Surface Wipe the controller with dry or wet clothe or soft paper towel Apply glass cleaner wit...

Страница 33: ...g 26 Fingerprint Controller Keypad Layout The controller s 4x4 keypad is shown above enters the system menu arms or disarms the system The system menu is organized in a multiple level structure and to...

Страница 34: ...ry default password is 000000 In order to secure the controller change the password after the first login and keep the password in a safe place Verify Administrator Fingerprint or Card After the syste...

Страница 35: ...ed item is displayed press to enter the corresponding menu System Setting In the System Setting menu the user can set basic functions such as system date time password etc Address Setting Address Sett...

Страница 36: ...as a six digit number YY MM DD The year must be in the range 2000 2099 Press to confirm the new date The date and time can be set at the controller However if the fingerprint controller is connected t...

Страница 37: ...fore the user can configure the controller via the keypad The factory default system password is 000000 It is recommended that the password is changed after the initial log in for maximum security Be...

Страница 38: ...its press at any time will exit the menu Set Language Under the System Setting Menu press to at the below screen to enter language Setting Wiegand 34 bits Wiegand 34 bits Wiegand 34 bits Wiegand 34 bi...

Страница 39: ...een Enabled Disabled Press to exit Note the timer server setting takes effect when leaving the menu System Info Press at the below window to get into sytem information page Then the number of users an...

Страница 40: ...rm the action Press to confirm and perform the reset action User Setting User setting can be configured using either the fingerprint controller or the EverAccess Flex Series software Adding new user o...

Страница 41: ...shown After the fingerprint is read the controller will prompt Then controller will require you add the second fingerprint You can either use same finger or other finger The other fingerprint can be...

Страница 42: ...fingerprint controller will prompt users to confirm the deleting option The card number of the user is shown in the screen as well A sample screen is shown below Press to delete this user at the abov...

Страница 43: ...ge administrator setting One of the above two screens will be shown after entering into admin setting Press to toggle and confirm Press to exit ARM Setting If a card with arm disarm function is swiped...

Страница 44: ...ue to press to go through the following instructions Refer to section Add a User for the purpose of two fingerprints Please follow the instruction till successfully setting the fingerprint shown in th...

Страница 45: ...de Press under the below window to enter the set PIN setting Enter new PIN as following instruction and repeat it in the next window shown as below samples Note the PIN must be 6 digits Press to confi...

Страница 46: ...u Use and to choose from different menu options All menu options under Door Setting are introduced below Door Access Schedule Setting The first submenu in Door Setting is Door Access Schedule Setting...

Страница 47: ...ard or Fingerprint Users must provide either card or fingerprint to gain access No PIN is required 9 Card PIN or Fingerprint Users must provide either a combination of card plus PIN or a fingerprint t...

Страница 48: ...after the door is opened This time period is call door hold open time or door over time According to this setting EverAccess controller will determine whether to generate an alarm or not after the do...

Страница 49: ...for example the granted access the denied access and so on Some events are critical which must trigger the alarm output like the firm alarm input the zone alarm input and etc But some events are not...

Страница 50: ...rm in this chapter In case of fire alarm input controller will generate fire alarm output according to this setting By default both alarm outputs are active per Fire Alarm event At the following subme...

Страница 51: ...n User event will be generated when an unknown card is swiped on the reader or an unregistered fingerprint is collected from the fingerprint module Use steps outlined in Fire Alarm submenu to change s...

Страница 52: ...enerated when the door sensor detects that a door is opened without approve access request for example any legitimate swipe card or a valid fingerprint or door open button push operation taking place...

Страница 53: ...ns All menu options under Arm Zone Setting are introduced below Set Active Arm Zone Setting An alarm input can be simply enabled or disabled by setting an active arm zone The following window appears...

Страница 54: ...r the minute field and second field or exit without effecting any change Alarm Output Mode Alarm output mode defines how the two alarm output relays respond to the alarm input Two alarm output modes a...

Страница 55: ...r its 4 alarm inputs and can treat alarm inputs in a very flexible manner These 4 arm zones can be armed or disarmed on the controller globally as described below Also the individual arm zone can be a...

Страница 56: ...d then arm all active arm zones Reset the Alarm When system is generating an active ongoing alarm output follow the procedure below to reset the alarm At the window showing system time repeat step 1 t...

Страница 57: ...49 49 49 49 Press to reset the alarm If system is currently armed user will be prompted to disarm the system first Please refer to previous section for how to disarm the system...

Страница 58: ...up the user accounts who will use the software 3 Configure the controller and all other hardware settings 4 Configure the holidays access group and the door control schedule 5 Enroll the cards and set...

Страница 59: ...software Click the add button give the RS485 address for the controller set the serial port for the controller and click the submit button to connect a controller If the wiring is correct and the addr...

Страница 60: ...s and at specified times Set the access rules for the access group here And assign the cardholder to a certain access group in the next step 3 Configure the door control schedule On the Flex series co...

Страница 61: ...m EverFocus that includes a Hamster Plus USB fingerprint reader or buy it directly from Secugen www secugen com Users need to install the Secugen USB reader driver and connect the fingerprint reader t...

Страница 62: ...54 54 54 54 Notes...