3.10 CONTROL SETUP MENU
In the
CONTROL SETUP MENU,
we define :
(1) RS 232:
BAUD RATE:
There are 5 different speeds that can be used to transmit instru ction or
information through the RS232 port on the device, which are
2400, 4800, 9600,
19200, 38400
and
57600
BPS. The default setting from the factory is 9600 BPS.
STOP BIT:
Select stop bit :
1
or
2
.
PARITY:
Select parity level :
NONE, ODD or EVEN
.
DATA BIT:
Select data bit :
7
or
8
. The default setting from the factory is 8.
Note:
RS 232 pin definition is shown in
APPENDIX A
.
(2) RS 485:
BAUD RATE:
There are 5 different speeds that can be used to transmit instru ction or
information through the RS485 port on the device, which are
2400, 4800, 9600,
19200, 38400
and
57600
BPS. The default setting from the factory is 9600 BPS.
STOP BIT:
Select stop bit :
1
or
2
.
PARITY:
Select parity level :
NONE, ODD
or
EVEN
.
DATA BIT:
Select data bit :
7
or
8
. The default setting from the factory is 8.
Note:
RS 485 pin definition is shown in
APPENDIX B
.
(3) RS 232 / RS 485 ID:
Select ID from
001
to
255
.
(4) PTZ PROTOCOL:
Select PTZ protocol from
EVERFOCUS
,
PELCO-D, PELCO-P
and
ED2200/2250.