MATERIALS
Inner shell - duplex Stainless Steel
Coil - 22mm diameter Stainless Steel
Bosses - Stainless Steel
Every EVERFLO STAINLESS uV cylinder is water tested to a pressure
of 15 bar.
INSuLATION
Fire retardant polyurethane foam, nominal thickness 50mm.
The foam is CFC-Free and HCFC-Free.
The foam has an Ozone depletion Potential of Zero and a Global
Warming Potential of 3.1
CASEWORK
Zintec corrosion proofed steels throughout
durable, stove enamelled, gloss white paint finish
ANOdE
None fitted/none required
EXPANSION VESSEL
12 Litre size with 60, 90, 120 and 150 Litre models
18 Litre size with 180, 210 and 250 Litre models
25 Litre size with 300 Litre models
CONTROL SETTINGS
Pressure Reducing Valve - 3 Bar
Expansion Relief Valve - 6 Bar
Pressure and Temperature Relief Valve - 7 Bar/90°C
High Limit Thermostat in dual Thermostat - 85°C
High Limit Thermostat in Immersion Heater - 85°C
IMMERSION HEATER
1¾” BSP Parallel Threaded Head
Long Life Incoloy Sheathed Low Noise Element 14” Long
Long Life Incoloy Sheathed Thermostat Pocket 11” Long
Brazed Construction
Combined Thermostat and Safety Cutout
Element Rating 3kW at 240V A/C
APPROVALS
KIWA Approved to Building Regulations G3 & L
CE Compliant and fitted with a BEAB Approved Immersion Heater
SPECIFICATION SuMMARy
EVERFLO Cylinders offers the trade products backed by the service and technical
development skills that only a company of its size can.
All sites are licensed to British Standards Quality Assurance BS EN ISO 9001 : 2008 and
The manufacturer is a BSi registered firm. This means that all manufacturing plants are
monitored by an independent inspectorate and the quality systems employed , meet the
stringent requirements set down.
Specifiers, users and stockists can depend on Everflo for consistent quality and supply.
Everflo Cylinders have a policy of continuous product development and may introduce product modifications from time to time.
As a consequence details given in this brochure are subject to alteration without notice. E&OE.
Benchmark places responsibilities on both manufacturers and installers. The
purpose is to ensure that customers are provided with the correct equipment for
their needs, that it is installed, commissioned and serviced in accordance with
the manufacturer’s instructions by competent persons and that it meets the
requirements of the appropriate Building Regulations. The Benchmark Checklist
can be used to demonstrate compliance with Building Regulations and should be
provided to the customer for future reference.
Installers are required to carry out installation, commissioning and servicing work in
accordance with the Benchmark Code of Practice which is available from the Heating
and Hotwater Industry Council who manage and promote the Scheme. Visit www.
centralheating.co.uk for more information.