EverExceed Titan Series Скачать руководство пользователя страница 11

9.Maintenance and Cleaning

Replacing the Thermal Fuses
Using incorrect thermal fuses may irreparably damage the solar charge 
controller.

Only use the thermal fuses included in the scope of delivery

1. Open the solar charge controller as described in section "Opening the 
solar charge controller"
2. Remove the broken thermal fuses from the sockets (A and B).
3. Insert new thermal fuses (included in the scope of delivery).
4. Close the solar charge controller as described in section "Closing the 
solar charge controller"
5. Remember always connect the batteries before the solar panels or you 
will permanently damage the controller.

Note: To clean simply wipe the outside with a lightly dampened cloth. If unit 
has been opened use an air spray such as a keyboard cleaner to blow out 
the internal dust that may accumulate inside the controller .

Cleaning the Cooling Fin

Clean the Fan air vents and internal cooling fan regularly by using a dry or 
slightly damp cloth to wipe.
Attention:

Liquid detergent or corrosive solvent cleaning are forbidden.

Liquid is not allowed in the device.

Clear the air vent passage.

Carefully remove dirt with a suitable soft brush if deemed necessary .

10.Storage and waste disposal

 

Store the charge controller in a dry place with ambient temperatures 
between -40 °C and +75 °C.
Disposal
Dispose of the solar charge controller at the end of its service life in 
accordance with the disposal regulations for electronic waste which 
apply at the installation site at that time.

11.Recovery Processing and Warranty

Recovery Processing
When the controller abnormal, please check the following question and 
contact the customer service representative. 
Controller failure mode

Please check the fault tips in the failure mode, and then proceed to the 
appropriate troubleshooting;
When the controller does not start properly:
1. Check the controller external solar panels with the correct polarity .
2. Check Battery Connection;
3. Check Battery;
4. Check circuit breaker;
5. Check internal fuse;
If the problem persists , please contact the customer service

Please offer the following information

Equipment information: Model, 

Order No., serial-number(Stickers on the rear plate); Detailed description 
of the problem
(Type of system, occasionally/frequent problems, indicator light, data 
display, and so on ).

Warranty
Within the warranty period, it is free to repair for the non-human fault. 
Otherwise, should charge the cost of repairs.

19

20

www.everexceed.com

www.everexceed.com

9.1 

9.2 

10.1  

10.2 

11.1

11.1.1 

11.1.2 

11.2 

Содержание Titan Series

Страница 1: ...Titan Solar Charger Controller User Manual Titan Series www everexceed com ...

Страница 2: ...e controller Please take good care of this manual for future reference whenever necessary The If you violate the operation rules it would endanger personal If you violate the operation rules it would endanger personal Contents 1 Notes on This Manual 2 Safety Instructions 3 Unpacking 4 Assembly 5 MPPT controller Connection 6 Meaning of LED LCD and function key 7 Parameter Setting 8 MPPT and PC Conn...

Страница 3: ... skilled person The Controller is not to be used by children or persons with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction 2 1General Safety Instructions Warning Caution Surface may be extremely hot and may cause burns Do not touch the enclosure of the charge controller during operation If possible keep in...

Страница 4: ...he solar charge controller please read all instructions and cautionary markings on the solar charge controller and all corresponding sections of this guide Please use components and parts recommended or sold by EverExceed Otherwise may result in a risk of fire electric shock or injury to person To avoid a risk of fire and electric shock make sure that existing wiring is in good condition and that ...

Страница 5: ... 4 Assembly 4 1 Operator technical personnel 4 2 Selecting the Mounting Location Danger Danger to life due to fire or explosion The charge controller enclosure can become hot during operation Do not mount the charge controller on flammable construction material Do not mount the charge controller near highly flammable materials Do not mount the charge controller in potentially explosive areas Do no...

Страница 6: ...y using a disconnection unit and secure it against accidental reactivation Disconnect the circuit breaker and ensure that it cannot be reconnected Ensure that no voltage is present in the system Warning Risk of injury due to electric shock If all cables with different voltages are routed in parallel damaged cable insulations may lead to a short circuit Route all cables separately Warning Over volt...

Страница 7: ...e output voltage range based on the type of battery bank system Like the battery bank voltage is 48V DC output voltage range will be the range of 48V battery bank working voltage 1 How to turn DC output turn on off Please find the DC output control through MPPT or Monitoring software have 6 way to control it ON Mode OFF Mode Time Control Mode PV Volt Ctrl PV Time Ctrl Details please check the Sett...

Страница 8: ... breaker make sure PV and controller disconnect Warning When the controller is charging for battery please do not turn off the breaker with battery before PV input have not turn off Or the machine will have unrecoverable fault and this will not in the warranty 6 Meaning of LED LCD and function key 6 1Panel Description Meaning of LED and function key LEDs and buttons Instruction CHARGE Blue Control...

Страница 9: ...mode Press ENTER2 button for 3 seconds change on mode or off mode the LOAD indicator light changes at the same time The LOAD indicator light DC output on The LOAD indicator dark DC output off Number Types 00 User defined by PC software 01 Gel 02 NiCd 03 Sealed 04 Vented 8 MPPT and PC Connection Overview Get into main interfaceas following Com Setting Com Get into set the connection of Solar Eagle ...

Страница 10: ...roller to battery will automatically start Step 3 Connected PC and controller with RS232 and PC will notice the communication at this time the PC will chose COM1 Step 4 Open the software as administrator WIN 7 of 8 then press to choose COM communication and enter It will automatically connect Step 5 A The software is now ready to be used 2 Customer do not have PC connector If customer do not have ...

Страница 11: ...if deemed necessary 10 Storage and waste disposal Store the charge controller in a dry place with ambient temperatures between 40 C and 75 C Disposal Dispose of the solar charge controller at the end of its service life in accordance with the disposal regulations for electronic waste which apply at the installation site at that time 11 Recovery Processing and Warranty Recovery Processing When the ...

Страница 12: ... Rated Output Current 12V 24V 48Vsystem 15A 20A 25A 30A 40A 12V 24V 48Vsystem 20A 25A 30A 35A 45A Current limiting Protection Temperature Factor 12V 24V 48Vsystem 0 02 Temperature Compensation 12V 24V 48Vsystem 14 2V The highest temperature 25 0 3 Output Ripples speak 12V 24V 48Vsystem 200mV Output Voltage Stability Precision 12V 24V 48Vsystem 1 5 Output Discharge Characteristics Output Discharge ...

Отзывы: