ELECTRICAL CONNECTIONS
LOCAL AUTHORITY REQUIREMENTS
Installation is only permitted by an authorized person, and carried out according to instructions
provided by the manufacturer. Incorrect installation might cause harm and damage which the
manufacturer accepts no responsibility.
ELECTRICAL INSTALLATION
Before carrying out the connection to the power supply, the voltage rating of the appliance (stamped on the
appliance identification plate) must be checked for correspondence to the available mains supply voltage, and
the mains electric wiring should be capable of handling the oven’s power rating (also indicated on the
identification plate).
NOTE: For connections to the mains power supply, never use adapters, reductions or multiple power points as
these may overheat and catch fire.
A circuit breaker with a contact opening of at least 3 mm must be installed
inside the supply circuit.
After having installed the appliance, the switched outlet must always be in an accessible position.
The electrical safety of this appliance can only be guaranteed if the cooker is correctly and efficiently earthed.
The manufacturer declines all responsibility for damage resulting from a system which has not been earthed.
WARNING: It is essential to use specific soft wire or specific groupware bought from the manufacturer or
maintenance department to replace if the electrical soft wire has been broken.
IMPORTANT: The following figure shows the connection details and minimum diameters of supply cables that
must be used for both single and three phase connections:
WARNING: For single phase connection, three shortcut circuit bridges must be installed as seen in the above picture.
If shortcut circuit bridges are not installed properly, some cooking zones do not operate.
These ovens must be connected to a 220-240V 50Hz power supply. They are earthed via the supply cord. The
earthing cable must be connected via the screw with the earthing mark.
The switched outlet must be connected to a suitable earth wiring, in conformity to current safety regulations.
The cooking appliance must be connected to a switched outlet. It should not be located above the appliance
and no more than 1.25m away from it. The power supply cord must not touch against any hot surfaces and
must be placed so that its temperature does not exceed 75 °C at any point along its length.
The mains terminal block is located at the rear of the oven and the terminals are accessible by removing the
terminal block cover.
If the mains supply cable is damaged during or after installation, it must be replaced by a licensed electrician
with a cable supplied by the Authorised Service Centre.