background image

 

 

 

 

- 6 - 

 

Know the rules 

Every people who operate or maintain the equipment should know the 
meaning, rules and laws in terms of equipment handling. They should 
know also the traffic rules, fire service act, emergency measures and 
where the relief equipment is. 

Keep the fire extinguisher and the first-aid case in the operator

‟s cabin 

for emergency use. 

 

Figure 4 

 

 

1.2. Preparation for safe operation 

 

WARNING! 

Read and observe the following instructions on safety. 

 

 

Install the grab on the suitable carrier 

The suitable carrier must be selected taking the weight and hydraulic system of the grab into consideration. 
The carrier may fall over if the grab is installed on the carrier, which does not fit the grab. All hydraulic lines 
for the grab use must satisfy the specification and quality provided in page 15, 

“5.2. Requirements on the 

carrier

Protect the operator from the flying splinters 

To protect the operator from the heavy concrete elements falling down when the grab is working on the tall 
columns, supports and brick, the carrier should be equipped with the cab protector strong enough for the 
falling elements. For more information on the cab protector, please consult carrier manufacturer or 
EVERDIGM dealer. 

Safety instructions on the grab installation 

When insert the mounting pin to install the grab on the carrier, the pin holes in the carrier

‟s arm must be flush 

with those in the mounting adapter of the grab. For this job, an carrier operator and an assistant should be 
careful and agree on the hand signals beforehand. Your finger or hand must not used to check whether the 
holes are flush. Once the mounting pins are inserted, lock the pins so that they are not taken off.   

If quick coupler is used, be sure clamping is completed. When you connect the hose, tighten the connectors 
with prescribed torques. 

And make sure of complete connection when you open the stop valve. It may cause personal injury if the 
incorrectly connected hose is pressurized. When connecting the hose, be careful not to have the o-ring 
damaged or missed, and keep all the connectors clean. 

Содержание EPG05

Страница 1: ...OPERATION MAINTENANCE MANUAL Multi Purpose Grab Document No MSAGUS 0005 Revision Date 2014 09 23...

Страница 2: ...may be changed If you found the parts unclear or not corresponding to the grab call and consult EVERDIGM dealer or service center Important information on safety is described in the safety information...

Страница 3: ...3 Technical specifications 12 4 Markings and labels 13 5 Installation 15 5 1 Lifting the grab 15 5 2 Requirements on the carrier 15 5 3 Installation of hydraulic piping on the carrier 17 5 4 Mounting...

Страница 4: ...ever fail to read and observe the instructions for safe operation Signal Words The words DANGER WARNING CAUTION and IMPORTANT appeared with the above Safety Alert Symbol indicate degree of risk of haz...

Страница 5: ...ly and is placed stably in the safe place Figure 1 Know your equipments Never fail to read and understand the safety messages operation manual and maintenance manual before installation and operation...

Страница 6: ...ents falling down when the grab is working on the tall columns supports and brick the carrier should be equipped with the cab protector strong enough for the falling elements For more information on t...

Страница 7: ...or operating the grab WARNING The following instructions are on safety in operation with grab Read understand and observe the instructions More information is provided in page 23 6 3 Operation Never o...

Страница 8: ...ood condition Ensure that the grab and carrier stop completely Maintenance work should be performed with the grab completely closed Make sure to shut off the stop valve of the hydraulic line for the g...

Страница 9: ...may be slippery The oil wet on the ground may be very slippery Collect any oil and dispose it correctly Do not alter or modify Unauthorized alteration or modification of the grab shall not be guarante...

Страница 10: ...ndard accessories fittings hoses etc 2 2 Option components The following parts are to be supplied as option only Standard mounting adapter 1 can be installed on most popular carriers Mounting pin bush...

Страница 11: ...11 2 3 Mounting dimension for the adapter plate EPG05 EPG08 Figure 9 190 190 430 400 160 100 100 25 20 Figure 10...

Страница 12: ...erating Oil Temperature C 20 90 Recommended Carrier Weight 2 tonne 4 8 7 10 Hose Connections Main Pressurizing Port MA Grab Closing Pressurizing Port MB Grab Opening Rotation at the view from carrier...

Страница 13: ...Pay attention to the marks and labels related to safety EVERDIGM Logo CE Label Stay Clear Indicates that the distance must be kept to be safe from the flying rock splinter Lifting Point Indicates the...

Страница 14: ...he manuals prior to initial use and follow the Do not operate when bystanders are in working area cab using the necessary window guarding The operator must be adequately protected within the Risk of S...

Страница 15: ...and low crushing force respectively Check the specification of the carrier For the hydraulic grab the inner diameter of the hydraulic line must be correspond to page 12 3 Technical specifications or b...

Страница 16: ...to grab piping lines take the return line of the existing breaker piping lines for the grab closing lines of the grab If the return line of the existing breaker lines is also installed for low pressu...

Страница 17: ...maximum pressure in grab opening and closing operation Flow control valves to adjust working speed and rotation speed but it is necessary not to exceed recommended speeds otherwise hydraulic motor and...

Страница 18: ...ke care of the direction of the mounting adapter as the drawing Set the carrier s engine speed to low idle and move the stick of carrier slowly until its hole is aligned with that in the mounting adap...

Страница 19: ...injury Match the holes by only visual lining up While moving the carrier make sure that there is no person in the vicinity of the carrier Personal injury can result also from dropping the mounting pin...

Страница 20: ...RB Place a pressure gauge into either port and set the minimum pressure unscrewing the pressure relief valve to the end The pressure gauge must be for 400 bar or more Place the grab to the ground or t...

Страница 21: ...ow control valve in the carrier s rotation pipe The proper rotation speed is 7 12 rpm and it must not exceed 15 rpm IMPORTANT It will cause personal injury damage to the grab or inconvenience operatio...

Страница 22: ...ng of the grab no abnormal sound and no vibration during the operation WARNING Read carefully and follow all safety regulations concerned with the preparation for safe operation Refer to page 6 1 2 Pr...

Страница 23: ...please stop the carrier and wait until the oil has cooled to operating temperature range For continuous operation with high duty maximum oil temperature is recommended not to exceed 80 C 175 F An auxi...

Страница 24: ...ry or death Never operate the grab unless you are properly trained DANGER Figure 17 DO CRUSHING FROM THE TOP DOWNWARDS Always be careful of falling down of broken elements When crushing columns chimne...

Страница 25: ...a where high pressure piping or similar gas piping was laid out High pressure gas piping can be explosive at damage WARNING IMPORTANT Figure 21 DO NOT USE FOR TRANSPORT PURPOSES The hydraulic grab is...

Страница 26: ...IMPORTANT Figure 24 DO NOT SUPPORT THE CARRIER WITH THE GRAB Never support the carrier s weight with the grab i e jack up with grab to rotate the carrier s undercarriage This will cause serious damage...

Страница 27: ...igure 28 DO NOT ROTATE THE GRAB WHILE CRUSHING IS IN PROGRESS This will cause damage to the grab and carrier s arm IMPORTANT NEVER ATTEMPT TO DO UNALLOWED JOB Do not attempt to do job other than open...

Страница 28: ...28 Please consult EVERDIGM dealer for the operation in special applications such as underwater use cutting high temperature object bitting off ladle slag in iron works...

Страница 29: ...grab visual inspection Check whenever inspecting if there are oil leaks at the hydraulic components or the hydraulic connections of the grab Check whenever inspecting if all fasteners such as bolts nu...

Страница 30: ...if there is a crack in the welded part of the grab Check the hydraulic components of the carrier Check abnormal sound or vibration during the grab movements and rotation of the grab Every 1000 hours o...

Страница 31: ...7 Hex head 7 8 M10 x 1 5 8 Hex socket 7 8 M12 x 1 75 19 Hex head 12 14 M12 x 1 75 10 Hex socket 12 14 M14 x 2 22 Hex head 19 21 M14 x 2 12 Hex socket 19 21 M16 x 2 24 Hex head 30 33 M16 x 2 14 Hex soc...

Страница 32: ...used Using the oil with higher viscosity too thick may cause Generating shock while cylinder is in operation Risk of failure in the pumps and rotation motor Life time of hydraulic oil filter shortene...

Страница 33: ...s Oil filters Every 100 hours Oil cooling The maximum permitted hydraulic oil temperature in continuous grab operation is 90 C 194 F Therefore a reliable hydraulic oil thermometer is necessary If ther...

Страница 34: ...open Take care of the safety against the grab after dismounting so that it can t fall over After turn stop valves to OFF position disconnect hydraulic hoses from the stop valves Apply end caps and plu...

Страница 35: ...rect operating pressure or contact EVERDIGM service Defective relief valve Contact EVERDIGM service Grab can not rotated or abnormal noise during rotation Hydraulic motor pinion or slewing bearing are...

Страница 36: ...36 Notes...

Страница 37: ...37 Notes...

Страница 38: ...on s Valley 680 Gasan Dong Geumcheon Gu Seoul Korea 153 803 Tel 82 2 801 0800 Fax 82 2 801 0899 Head Office 332 3 Janggwan ri Jincheon eub Jincheon gun Factory Chungcheongbuk do Korea 365 802 Tel 82 4...

Отзывы: