9
Charging current selection.
For the first 8 seconds after the batteries are inserted user
can adjust charging current by pressing the “Current”
button. Possible values are: 200, 500, 700 and 1000mA.
Changes are applied for all inserted batteries. Charging will
start automatically after 8 seconds from the moment last
button was pressed. If further changes are needed, user
can select desired charging slot (“1,2,3,4” button) and
change mode/current anytime by using “Mode” followed
by “Current” button.
Please note that the recommended charging current
should be set to about 1/4 value in relation to inserted
battery’s rated capacity. For example for the 2000mAh
R6/AA batteries the recommended charging current is
500mA. For the 800mAh R03/AAA batteries the
recommended charging current is 200mA.
Full charge termination method -∆V is less accurate with
lower than recommended charging currents.
7.
Overheat protection.
This charger is equipped with
overheat protection. Protected are
both the inserted batteries and the
charger. If temperature of any of the
inserted cells rises over 55 degrees
Celsius or the charger’s internal
circuitry temperature rises over 70