6. Heating & Cooling
Heating elements are made from low watts density incoloy to present undue built up
of scaling. The heat exchanger (COOLER) is a weld plate to minimize the effect from
uneven expansion and to give a large cooling surface for greater performance.
7. The Fluid Pump
The pump is of Magnetic Drive Pump.
8. The Electrical System
Some details of the electrical system, for maintenance purposes, are in the date
sheet of this manual. Please note: the control voltage is 24V. Always check carefully
before fitting replacement parts.
Power ON/OFF is the
RED
handle on the front panel which interlocks with the mains
isolator.
All control switches are LED indicators are identified by icons for easy recognition of
functions and faults.
Heater and pumps contactors and pump overload are all housed in the self
contained electrical cabinet. This lies behind the front panel which hinges
downwards for easy access.
Heating and cooling functions are switched on and off automatically by the printed
circuit board. This is achieved with a hybrid PCB circuit board and a J type
thermocouple.