Factory Default Settings
Time Source -
Internal
Time Code Format -
0
Auxiliary Channel Input Gain -
0.0 dB
Auxiliary VOX threshold level -
+16 dB
Auxiliary VOX hold time -
6 seconds
Telephone Channel Input Gain -
0.0 dB
Telephone Record Activation -
VOX
Telephone VOX threshold level -
+16 dB
Telephone VOX hold time -
6 seconds
Record priority -
Telephone takes priority
Phone line beep tone -
Disabled
Sampling -
32
kbps
User password -
00000
Security level -
High
Call counter -
Cleared on power-up
ANI source -
Internal caller ID
ALI phone number location -
Line #1 Column#1 Length 10
External time source IO port configuration -
19200 baud, 8 data bits, no parity, 1 stop bit
Caller ID/ANI IO port configuration -
19200 baud, 8 data bits, no parity, 1 stop bit
ALI IO port configuration -
19200 baud, 8 data bits, no parity, 1 stop bit
Remote control IO port configuration -
19200 baud, 8 data bits, no parity, 1 stop bit
Autorestore -
0.25 seconds
Traffic -
Light
Above is a list of those parameters that can be configured by the user, with the factory defaults.
If the default settings are suitable for your application, you need only set the date and time and
the (optional) password security feature and your unit will be ready to use. Instructions for
changing the other setting are given below.
For the initial configuration of the unit, from the MAIN screen press the SYSTEM soft key.
SYSTEM Screen
SYS INFO Screen
Press the SYS INFO soft key. The SYS INFO screen displays the unit serial number, the current
firmware version, and the amount of memory installed. Press the DONE key to return to the
SYSTEM screen.
Press the CONFIG soft key. The screen will ask for a password. Factory default is 00000, you
can simply hit DONE. See below for setting a password of your own.
ENTER CONFIG/PASSWORD Screen - Ignore at this time. See below for setting password
Configuration, System Information
CONFIG SYS INFO DONE
Unit Serial Number: 911R00000
Current Firmware Version: 1.00
Memory Installed: 16 Megabytes
DONE