ELECTRIC INSTANTANEOUS WATER HEATER
PPE1, PPE2, PPVE
12
1 | SAFETY INSTRUCTIONS
1.
Read and strictly follow the installation and operating instructions to ensure a long life and reliable unit operation.
2.
The unit is designed to be wall mounted.
3.
The unit can only be used when in perfect technical condition and correctly assembled.
4.
The maximum inlet water temperature should not exceed 60°C.
5.
Devices PPE2, PPE1 or PPVE should be installed in such a way as to temperature adjustment during standard usage in shower mode
had the priority over any other users who set water temperature during standard usage in other points of use.
6.
The unit should always be vented before initial start-up. Vent the unit each time after the water has been emptied from the
heater or pipes (e.g. when water supply system has been repaired or maintained).
7.
Connection to the mains and measurement of fire protection effectiveness should be made by a qualified person.
8.
Water heater must be unconditionally connected to protective grounding-the quality of which (continuity of the protective conductor)
should be checked periodically by qualified electrician. It is recommended to install heater on grounded, steel or copper
hydraulic fittings.
9.
The unit must be permanently connected to the mains which is equipped with earth clamp.
10.
According to the general norms, electrical installation must be equipped with currentdiferential switch of high sensitivity
(of max rated current 30 mA), whereby we recommend installing a separate four-pole residual current circuit breaker
(regardless of the remaining part of the installation) of current 10 or 30 mA
11.
The unit must not be installed in the place which is exposed to the danger of explosion and place in which the temperature
may go down below 0°C.
12.
Storage of water heater in the rooms where temperature drops below 0 degrees may result in its damage
(there is water inside the device) and may eventually lead to the loss of warranty rights.
13.
Do not use when the water has been emptied from the unit or pipes (e.g. when water supply system has been repaired or maintained).
14.
Unit’s cover must not be taken off while power is on.
15.
Failure to install the filter on water supply pipe can cause unit damage.
16.
Lime scale built up on heater’s elements may limit water flow and lead to heater’s damage. Such damages are not subjected to warranty
rights. Water heater and sanitary fittings should be periodically descaled, whereas, frequency this process should be adjusted to water
hardness in given installation. Lime scale built-up may be partially limited by usage of magnetic descalers installed on the cold water
inlet pipe
17.
Appropriate precaution must be taken when using hot water. Temperature of water over 40°C may cause hot feeling and can be
dangerous for children, whereas, temperature above 50°C may lead to first degree burn (espcially amongst small children).
18.
In accrodance with general norms new (or modernised) electrical installations must be equipped with over-voltage protection devices,
which is particularly important in case of buildings equipped with lightining installations. Electronic water heater is a device sensitive to
overvoltage, therefore, it is recommended to install it only in new (or modernised) electrical installations.
19.
Water heater should be mounted in such a way in order to enbale easy access for service and service repair. It is connected with
keeping minimal distance from the walls and the ceiling of min 100 mm.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities
or lack of experience and knowledge, unless they have been given supervision or instructions concerning use of the app-
liance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the app-
liance.