4
Manual
Reset
Limit
Switch
Figure 4
DGAT Series
Blower
Combustion
Fan Motor
Burner
Observation
Cover
Gas
Valve
System
Switch
Ignitor
Control
Ignition System —
Automatic Ignition Furnaces
The furnace is equipped with an ignitor and has no pilot
burner. When the wall thermostat calls for heat, the furnace
combustion fan starts. In approximately
30 SECONDS
, the
ignitor energizes, the gas valve admits gas to the main
burner and the gas is ignited.
If ignition does not occur, the ignitor will continue to operate
for approximately
7 SECONDS
. After
30 SECONDS
(the
combustion fan still running) the ignitor will energize again.
If ignition does not occur, the ignitor will continue for
7 SE-
CONDS
, and shut off. In approximately
30 SECONDS
the
ignitor will attempt ignition again.
If ignition does not occur after three attempts, the system
will lock out. The system must then be manually reset by
turning the wall thermostat to a point below room tempera-
ture, after waiting for
1 MINUTE
.
THE FURNACE CONTROLS AND THEIR FUNC-
TION
1.
System Switch
--- this system switch turns
ON
or
OFF
the 120 volt electrical circuit that powers the furnace
controls and the blower motor. The system switch must
be turned
ON
for the furnace to operate. Turn the
switch to
OFF
when oiling the blower motor, cleaning
the blower, etc.
2.
Fan Switch
--- this fan switch is a temperature sensing
device. When the furnace heats up, the switch auto-
matically turns the blower on. On the off---cycle, when
the furnace cools down, the switch turns the blower off.
3.
Limit Contro
l
--- this furnace is protected by two (2)
high temperature limit switches. The lower limit switch
is an automatic reset type.
IMPORTANT
THE UPPER LIMIT SWITCH NEAR LEFT SIDE OF
BLOWER
IS A MANUAL RESET TYPE LIMIT
SWITCH. (SEE FIGURE 4). IF BURNER DOES NOT
FUNCTION, TURN SYSTEM SWITCH TO
OFF
AND
PUSH RESET BUTTON IN CENTER OF LIMIT
SWITCH.
If the upper limit switch trips again soon after resetting,
turn the furnace System Switch to the
OFF
position and
call your authorized service technician.
CAUTION
THE CHUTE TO LEFT OF BLOWER IS HOT. USE
CARE WHEN RESETTING LIMIT SWITCH TO AVOID
BURNS TO HAND AND ARM.
4.
Gas Valve
--- gas valves are 100% shut---off type and
will fail safe if for some reason the gas is turned off or
the pilot goes out. They are also of the modulating or
“
step--open
” type which means they open to a “
low
fire
” position and after a few seconds “
step--open
” to
“high fire
”.
Содержание DGAM Series
Страница 19: ...18 WIRING DIAGRAMS DGAT Series Ground Screw To Earth Ground Ground Screw to Earth Ground...
Страница 20: ...19 DGAM Series Ground Screw To Earth Ground Ground Screw to Earth Ground...
Страница 21: ...20 DLAS Series Ground Screw To Earth Ground Ground Screw to Earth Ground...
Страница 24: ...23...