EVCO S.p.A.
Vcolor 818
| Installer manual ver. 1.1 | Code 144VC818E114
page 34 of 94
6.8
Temperature-controlled
soft
deep
freezing
and
storage
The temperature-controlled soft deep freezing and storage cycle is divided into the following three phases:
-
deep freezing soft phase
-
deep freezing
-
storage.
On conclusion of a phase, the device passes automatically to the next.
Operate as indicated to start the cycle:
1.
Make sure the device is in the "on" status.
2.
Make sure that the keyboard is not locked and that no procedure is in progress.
3.
Press and release the key (1);
Press and release the key (2) and then press and release the key (3). The device will display the deep freezing end
temperature and the work set-point during deep-freezing.
4.1
Press and release the MENU key and then press and release the key (4) or the key (5) to select the deep
freezing end temperature and the work set-point during deep freezing.
4.2
Press and release the key + (6) or the key – (7) to modify these values and then the ESCAPE key to memorise
them; these values can also be memorised through parameters r4 and r8.
5.
Press and release the START/STOP key (1): the test to verify the correct insertion of the needle probe will be
started; see paragraph 6.14 " Test for verification of the correct insertion of the needle probe".