EVCO S.p.A.
Vcolor 869/879
| Installer manual ver. 2.2 | Code 144VC869E214
page 28 of 94
With temperature controlled cycles, a test is performed to check the correct insertion of the needle probe in the food to
be blast-chilled. Should the test not succeed, the cycle is automatically converted to the time mode, the buzzer beeps
and the icon symbolizing an alarm underway is displayed. For further details on how to perform the test, see section
7.6.1.
While the cycle is in progress, the display will show the main set points. The graphic charting the temperature will be
displayed pressing the
key. The key will be displayed after 5 minutes from the cycle start and updates will take
place with a one-minute frequency. The cycle can be stopped at any time by pressing the
key.
On completion of the blast chilling/blast-freezing cycle, when the needle probe has reached the right temperature or the
time period is finished, the buzzer sounds and the conservation phase begins.
The conservation phase is not timed and is only terminated when the
key is pressed.