EVCO S.p.A.
Vcolor 869/879
| Installer manual ver. 2.2 | Code 144VC869E214
page 27 of 94
7.1
Blast chilling/blast-freezing and conservation
Pressing on one of these areas enables a blast chilling or blast-freezing cycle to be set. The following screen opens and
the
key is activated. If the needle probe is being used and there is no error, the cycle always defaults to temperature
control. To move to a time controlled cycle, press area
which will deactivate the needle probe area and the time
controlled area will be activated.
The cycle selected will use the preloaded settings for that cycle, but pressing area
makes it possible to change the
main settings, within the permitted range, which are shown on the display. To change all the various set points for the
phases of the selected cycle, expert mode can be enabled by pressing area
. Once all the settings have been done,
press area
to terminate the phase. The screen summarising all the setting data for the cycle will appear, as shown
below.
Press area
to save the program just set, or press area
to start up the cycle.