EVCO S.p.A.
EVFTFT618 | Installer manual ver. 2.2 | Code 144FTFT618E224
Page
12
of
62
4 ELECTRIC CONNECTION
4.1
Electric connection
The following drawing illustrates the EVFTFT618 electric connection.
The utility managed by the K4 output, depends on parameter u3, as follows:
-
dehumidifier (u3 = 0)
-
condenser fan (parameter u3 = 1).
For the settings relative to the parameters, see chapter 0.
The utility managed by the K8 output, depends on parameter u1, as follows:
-
pump down valve (u1 = 0, per-defined setting)
-
evaporator fan (u1 = 1).
For the settings relative to the parameters, see chapter 0.
The RS-485 port is for the connection of the controller to the following additional products:
-
Parameters Manager set-up software system
-
RICS plants monitoring and surveillance systems
-
device for recording data and to download recorded data (via USB).
The port must not be used simultaneously with more than one of these products.
USB port
RS-485 port
ground
Power supply
Evaporator
fan at
EVCFAN1
h
u
m
id
it
y
c
e
ll
mains
electricity
D
e
h
u
m
id
if
ie
r
(c
o
n
fi
g
.)
h
u
m
id
if
ie
r
c
a
b
in
e
t
li
g
h
t
c
o
m
p
re
s
s
o
r
d
e
fr
o
s
ti
n
g
c
o
m
p
.
c
ir
c
u
it
h
ig
h
p
re
s
s
u
re
lo
w
p
re
s
s
u
re
s
te
a
m
g
e
n
e
ra
to
r
h
e
a
ti
n
g
e
le
m
e
n
ts
mains
electricity
Power supply
Control module
User interface