59
Technical parameters
The list of CT coils that are supported by the Audi Wallbox by default can also be obtained
from chapter Set DIP-switches (page 49).
In addition to the CT coil models mentioned in chapter Set DIP-switches, the CT coil models
that are possible to use as default with any variant of the Audi Wallbox are listed.
In addition to the CT coils supported by the Audi Wallbox by default, the Audi Wallbox plus
and pro offer the possibility to also use other CT coils with different technical parameters.
However, these parameters need to be configured in the Audi Wallbox's Configuration
Manager during electrical commissioning. The table below is listing the limitations of the
technical parameters, that such CT coils need to fulfil.
Manufacturer
Model
Rated Primary Current (in A RMS)
Turn ratio
Nidec
C-CT-10
60
3.000 : 1
Nidec
C-CT-16
100
3.000 : 1
Nidec
C-CT-24
200
3.000 : 1
LEM
TT 50-SD
50
3.000 : 1
LEM
TT 100-SD
100
3.000 : 1
VAC
E4623-X002
40
2.500 : 1
VAC
E4624-X002
60
2.500 : 1
VAC
E4626-X002
100
2.500 : 1
Parameter
Value
min. rated Primary Current (in A RMS)
300
max. rated Primary Current (in A RMS)
200
min. Turn Ratio
300 : 1
max. Turn Ratio
10.000 : 1