3.7.16.4 Transfer Response
IOCS16#
This is an active low signal driven by an I/O-mapped PC-AT/PC104 adapter indicating that
the I/O device located at the address is a 16-bit device. This open collector signal is driven,
based on SA [15:0] only (not IOR# and IOW#) when AEN is not asserted.
MEMCS16# This is an active low signal driven by a memory mapped PC-AT/PC104 adapter indicating
that the memory device located at the address is a 16-bit device. This open collector signal is
driven, based on LA [23:17] only.
0WS#
This signal is an active low open-collector signal asserted by a 16-bit memory mapped device
that may cause an early termination of the current transfer. It should be gated with MEMR# or
MEMW# and is not valid during DMA transfers. IOCHRDY precedes 0WS#.
IOCHRDY
This is an active high signal driven inactive by the target of either a memory or an I/O
operation to extend the current cycle. This open collector signal is driven based on the
system address and the appropriate control strobe. IOCHRDY precedes 0WS#.
IOCHCK#
This is an active low signal driven active by a PC-AT/PC104 adapter detecting a fatal error
during bus operation. When this open collector signal is driven low it will typically cause a
non-maskable interrupt.
3.7.16.5 Controls
SYSCLK
This clock signal may vary in frequency from 2.5 MHz to 25.0 MHz depending on the setup
made in the BIOS. Frequencies above 16 MHz are not recommended. The standard states 6
MHz to 8.33 MHz, but most new adapters are able to handle higher frequencies. The PC-
AT/PC104 bus timing is based on this clock signal.
OSC
This is a clock signal with a 14.31818 MHz ± 50 ppm frequency and a 50 ± 5% duty cycle.
The signal is driven by the permanent master.
RESETDRV This active high signal indicates that the adapter should be brought to an initial reset
condition. This signal will be asserted by the permanent master on the bus for at least 100 ms
at power-up or watchdog time-out to ensure that adapters in the system are properly reset.
When active, all adapters should turn off or tri-state all drivers connected to the bus.
3.7.16.6 Interrupts
IRQ [3:7],
IRQ [9:12],
IRQ [14:15]
These signals are active high signals, which indicate the presence of an interrupting PC-
AT/PC104 bus adapter. Due to the use of pull-ups, unused interrupt inputs must be masked.
Содержание ECM-3610
Страница 29: ...ECM 3610 3610L ECM 3610 3610L User s Manual 17 3 4 Jumper Connector 3 4 1 Jumper Connector Layout...
Страница 92: ...User s Manual 80 ECM 3610 3610L User s Manual 5 Click the Next button or...
Страница 101: ...ECM 3610 3610L ECM 3610 3610L User s Manual 89 12 System will show as below...
Страница 103: ...ECM 3610 3610L ECM 3610 3610L User s Manual 91 15 Click Next to accept the settings...
Страница 106: ...User s Manual 94 ECM 3610 3610L User s Manual 2 On the System properties window click the Hardware tab as shown below...
Страница 107: ...ECM 3610 3610L ECM 3610 3610L User s Manual 95 3 Click the Device Manager button to show the Device Manager...
Страница 134: ...User s Manual 122 ECM 3610 3610L User s Manual 8 Click the Finish button to complete the display driver installation...
Страница 136: ...User s Manual 124 ECM 3610 3610L User s Manual 2 Select Install driver as shown below...
Страница 144: ...User s Manual 132 ECM 3610 3610L User s Manual 6 Measurement Drawing...