04.5 ICE ANTI-BLOCK FUNCTION

 

 

The pump cycles start automatically to ensure the perfect efficiency of the stove at any time, preventing its deterioration and any possible malfunction. When the 

temperature inside the boiler drops below 6°C, the system starts the pump to prevent the formation of ice.  

 

04.6 AUTOMATIC FILLING VALVE

 

 

Inside the stove is installed an automatic fill valve. It is enabled in the following cases: 

 

Low water level: the level sensor detects when there is very little water inside the boiler due to evaporation. The sensor sends a signal to the control unit 

which controls the solenoid valve.  

 

Thermal safety: it keeps the temperature inside the boiler under control in case of overheating. 

 

05 CLEANING AND MAINTENANCE 

 

05.1 INTRODUCTION 

 

The stove requires a simple yet constant cleaning to guarantee top efficiency and proper functioning.  

Constant maintenance by a qualified technician is recommended. 

The stove should be cleaned before the cold season because it can sometimes get clogged during the summer (by nests for example) preventing exhaust fumes 

to flow regularly. 

At the beginning of the season and in case of wind, a build-up of residue in the pipe may lead to fires. Should this happen, find below a few pieces of advice to 

follow: 

 

 

Block air supply to the pipe immediately; 

 

Throw sand or kitchen salt, and not water, to extinguish fire and coals; 

 

Keep objects and furniture away from the burning pipe. 

ALSO TO PREVENT THIS TYPE OF FAULT YEARLY CLEANING OF THE FLUE PIPE IS ESSENTIAL, REMOVING DEPOSITS OR ANY POCKETS OR 

OBSTRUCTIONS. 

 

05.2 DAILY CLEANING 

 

Any cleaning operation must be performed when the stove is completely cold: 

 

Empty the ash drawer: vacuum it out or dispose of the ashes in a waste bin. 

 

Vacuum the combustion chamber: check that there are no embers that may still be lit. In this case your dust vacuum cleaner will catch fire. 

 

Remove the ash inside firebox and on door.  

 

Clean the glass with a damp cloth or with a ball of damp newspaper dipped in ash. If the operation is performed with the stove hot there is a risk of the 

glass exploding.  

 

CAUTION: USE A DRY CLOTH TO CLEAN THE STOVE EXTERNALLY. DO NOT USE ABRASIVE MATERIALS OR PRODUCTS THAT COULD CORRODE 

OR WHITEN THE SURFACES. 

05.3 MANUFACTURER’S RESPONSIBILIES 

 

The manufacturer shall not be held liable against any direct and/or indirect, criminal and/or third party liability arising from: 

 

failure to abide by the instructions contained herein. 

 

non authorised repair operations or changes. 

 

use not compliant with safety rules. 

 

installation not compliant with national current regulations and safety rules. 

 

insufficient maintenance. 

 

the use of spare parts that are not original or which are not specific to the stove model. 

 

06 TROUBLE-SHOOTING 

 

 

The stove does not heat: the wood is too wet or of poor quality; insufficient chimney flue draught. 

 

The stove heats too: excessive chimney flue draught; door or drawer gaskets replacement.  

 

Bottom grate locked: check the grate and make sure there are no nails or wood pieces stuck in it. 

 

Blackened glass: wood too wet or of poor quality, poor draught, insufficient combustion air, register closed too quick. 

 

 

 

 

 

 

 

20

Содержание TL4S

Страница 1: ...INSTRUCTION MANUAL WOOD BURNING COOKERS EN TL4S...

Страница 2: ...TOVE EFFICIENCY p 13 03 6 INSTALLATION p 13 04 USING THE PRODUCT p 17 04 1 DISPLAY p 17 04 2 IGNITION p 18 04 3 COMBUSTION p 19 04 4 PRODUCTION OF DHW PLUS p 19 04 5 ICE ANTI BLOCK FUNCTION p 20 04 6...

Страница 3: ...watertight The wood to be used is as follows The wood log should have maximum 330mm in length and a maximum moisture content of 8 Dry wood produces more usable heat than wet wood as it produces less s...

Страница 4: ...cal substance concentration or to a high humidity level Do not use the appliance close to bathtubs showers basins sinks or swimming pools Do not install the appliance underneath an air vent Do not ins...

Страница 5: ...te even in absence of pressure heat dissipation devices backup water reservoir for quick achievement of the required operating conditions TECHNICAL DRAWING TL4S A 150 mm Scarico Fumi Flue Chemin e Rau...

Страница 6: ...ve 100 LEGEND REFERENCE DESCRIPTION COUPLING A SYSTEM FLOW 3 4 GAS R SYSTEM RETURN 3 4 GAS B BOILER DISCHARGE OUTLET 3 4 GAS C DOMESTIC COLD WATER INLET 1 2 GAS D DOMESTIC HOT WATER OUTLET 1 2 GAS E B...

Страница 7: ...ANITARY WATER INLET HOSE SANITARY WATER OUTLET HOSE AUTOMATIC RELEASE VALVE CONDENSATE DISCHARGE PIPE 3 4 HEATING COIL DOMESTIC WATER COIL MAGNESIUM ANODE FLOAT FLOAT SAFETY SOLENOID VALVE SAFETY SOLE...

Страница 8: ...ELECTRONIC CONTROL UNIT INTERNAL DIVERTER ADJUSTMENT DEVICE FLUE 150 mm OVEN INSPECTION PLATE 8...

Страница 9: ...he flue pipe must be carried out in a workmanlike manner and according to European UNI 10683 and national regulations local regulations and the technical specifications and warnings contained in this...

Страница 10: ...ue pipe joint connection with high temperature silicone sealant 1 000 C Should the existing flue opening not be perfectly perpendicular to the firebox fume outlet use an elbow to connect them Inclinat...

Страница 11: ...the penetration of rain or snow be constructed in such a way as to ensure in the event of winds coming from any direction the evacuation of combustion products be free of mechanical intake auxiliarie...

Страница 12: ...always results in an increased negative pressure and draught Horizontal wind results in an increased negative pressure as long as the chimney cowl was properly installed Descending wind always dimini...

Страница 13: ...ling your stove Select the position where the stove is to be installed and Arrange the connection to the flue pipe for fume extraction Provide the external air intake combustion air and check for its...

Страница 14: ...t the stove can draw the necessary quantity of combustion air this must be from an open space i e a space without exhaust blowers or providing adequate ventilation or directly from outside Do not inst...

Страница 15: ...e Eva Cal r boiler You must install a 3 way valve and a contact or a sensor that can control the valve Diagram 3 Wood burning stove fitted with boiler and separator for the production of domestic hot...

Страница 16: ...connections of the stove you should provide some gate valves so that you can disconnect it from the system if necessary The condensate resulting from boiling must be suitably conveyed and collected to...

Страница 17: ...dicates that the automatic fill valve is working L5 Pump indicates that the pump is working L6 Valve indicates that a 3 way valve is working Connections N POWER SUPPLY Neutral Ph POWER SUPPLY Phase N...

Страница 18: ...he automatic release valve open The system must be filled slowly so as to allow any air bubbles to come out of the stove exchangers If necessary bleed the radiators Fill the boiler tank you can use a...

Страница 19: ...nd amount of air by adjusting the register so that your stove functions properly according to the characteristics of the chimney flue and of the wood The top plate has been treated with food grade Vas...

Страница 20: ...CLEANING OF THE FLUE PIPE IS ESSENTIAL REMOVING DEPOSITS OR ANY POCKETS OR OBSTRUCTIONS 05 2 DAILY CLEANING Any cleaning operation must be performed when the stove is completely cold Empty the ash dr...

Страница 21: ...needed to correctly use operate and perform maintenance on the appliance CUSTOMER Signature DEALER INSTALLER Signature CERTIFICATE OF INSTALLATION AND TESTING CUSTOMER _______________________________...

Страница 22: ...t maintenance ____________ ____________ Technical Assistance Centre stamp Date 2nd maintenance ____________ ____________ Technical Assistance Centre stamp Date 3rd maintenance ____________ ___________...

Страница 23: ...haracteristics of the coating materials are excluded from the warranty the grains of the stones that are the main characteristic and that guarantee their uniqueness any small cracks or cracks that cou...

Страница 24: ...sponsibility for such disposal is to be borne by the owner and to not incur sanctions or adverse effects on the environment and health we recommend you contact the local administration the local waste...

Страница 25: ...tion totale ou partielle sans autorisation expresse de Eva Stampaggi S r l est interdite Die angegebenen Daten und Eigenschaften binden das Unternehmen Eva Stampaggi S r l nicht das sich das Recht vor...

Отзывы: