Diagram 4 - Wood-burning stove with puffer and various heating sources.
In this case the stove will be connected to various sources of heat. You must install a contact or a sensor to control the various heating appliances or any valves
or pumps.
HYDRAULIC CONNECTION
The hydraulic connection of the stove must be carried out by qualified staff, who must ensure the conformity of the entire system.
Particular attention should be paid when installing the stove in an existing system (see hydraulic diagram) to make sure that it will operate in perfect safety, in
compliance with the regulation in force.
The interior of the hydraulic system must be washed before connecting the stove. You need to install a expansion tank suitable for the system and adequate safety
valves.
ATTENTION: the average flow temperature is 55°C: take this value into consideration when choosing the heating system. The maximum operating pressure is 1.5
bar.
Upstream of the hydraulic connections of the stove you should provide some gate valves so that you can disconnect it from the system if necessary.
The condensate resulting from boiling must be suitably conveyed and collected to protect the floor.
If the KIT for the production of Domestic Hot Water is installed, the water used should have suitable characteristics so as to prevent the formation of limestone
inside the exchanger; water hardness > 25° French degrees, appropriate water softener.
The manufacturer declines any liability for any damage to persons or property arising from non-compliant product installation.
ELECTRICAL CONNECTION
The electrical connection must be performed by qualified personnel who install circuit breakers upstream of the appliance.
Special attention should be paid when the stove is parts of the system and all equipment must operate as planned.
Avoid installations with electric cables that run close to fume pipes or hot components that are suitably insulated.
The voltage is 230 V while the frequency is 50 Hz.
The electrical system where it is connected must be fitted with a conductor as required by the Regulations 73/23 EEC and 93/98 EEC.