ZW47 protocol Endpoint 3
Full Command Class Node Info
COMMAND_CLASS_ZWAVEPLUS_INFO,
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION,
COMMAND_CLASS_SWITCH_BINARY,
COMMAND_CLASS_SUPERVISION,
COMMAND_CLASS_SECURITY_2
The Below listed Command Class are all supported the Security S2
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION,
COMMAND_CLASS_SWITCH_BINARY
Z-Wave Configuration Parameters
1:Restores state after power failure
Paramter No: 1(0x01) Size:1 Byte Value: 00(default) The state before a power outage.
Value: 01 outlet on
Value: 02 outlet off
2:Power Wattage Report Value Threshold(Wattage) Value Scope :0----65535W
Paramter No: 2(0x02) Size:4 Byte Value: xx xx xx xx (Default 10W)
Value: 00 00 Disabled
3:Power Wattage Report Frequency (Timer) Value Scope :30----2678400S
Paramter No: 3(0x03) Size:4 Byte Value: xx xx xx xx (Default 30S)
4:Energy (kWh) Report Frequency (Timer) Value Scope :30----2678400S
Paramter No: 4(0x04) Size:4 Byte Value: xx xx xx xx (Default 300S)
5:Voltage (V) Report Frequency (Timer) Value Scope :30----2678400S
Paramter No: 5(0x05) Size:4 Byte Value: xx xx xx xx (Default 300S)
6:Electricity (A) Report Frequency (Timer) Value Scope :30----2678400S
Paramter No: 6(0x06) Size:4 Byte Value: xx xx xx xx (Default 300S)
You may use the below configuration parameters to change settings of the corresponding functionality.
Paramter No: 6(0x06) Size:4 Byte Value: xx xx xx xx (Default 300S)
7:Overload Protection (Current) Value Scope :1----16A
Paramter No: 7(0x07) Size:1 Byte Value: xx (Default 13A)
8
:
Endpoint1 Enable
Auto Turn-OFF Timer
Paramter No: 8(0x08) Size:1 Byte Value=0 Auto Turn-OFF Timer
Disabled (default);
Value=1 Auto Turn-OFF Timer
Enabled
9:Endpoint1 Count Down Configuration(Turn off the output by time)
Paramter No: 9(0x09) Size:4 Byte Value: xx xx Turn off Output
Value Scope :1----65535Minutes (default:60M)
10
:
Endpoint1 Enable
Auto Turn-ON Timer
Paramter No: 10(0x0A) Size:1 Byte Value=0 Auto Turn-ON Timer
Disabled (default);
Value=1 Auto Turn-ON Timer
Enabled
11:Endpoint1 Count Down Configuration(Turn on the output by time)
Paramter No: 11(0x0B) Size:4 Byte Value: xx xx xx xx Turn off Output
Value Scope :1----65535Minutes (default:60M)
12:Endpoint2 Enable
Auto Turn-OFF Timer
Paramter No: 12(0x0C) Size:1 Byte Value=0 Auto Turn-OFF Timer
Disabled (default);
Value=1 Auto Turn-OFF Timer
Enabled
13:Endpoint2 Count Down Configuration(Turn off the output by time)
Paramter No: 13(0x0D) Size:4 Byte Value: xx xx xx xx Turn off Output
Value Scope :1----65535Minutes (default:60M)
14:Endpoint2 Enable
Auto Turn-ON Timer
Paramter No: 14(0x0E) Size:1 Byte Value=0 Auto Turn-ON Timer
Disabled (default);
Value=1 Auto Turn-ON Timer
Enabled
15:Endpoint2 Count Down Configuration(Turn on the output by time)
Paramter No: 15(0x0F) Size:4 Byte Value: xx xx xx xx Turn off Output
Value Scope :1----65535Minutes (default:60M)
16:Manual Control
Paramter No: 16(0x10) Size:1 Byte Value=0
Manual Control Disabled
Value=1 Manual Control
Enabled
(default);
17:Status LED Configuration
Paramter No: 17(0x11) Size:1 Byte (default:Value=01 )
Value: 00 LED indicator will display power consumption whenever the device is plugged in
Value: 01 LED indicator will display power consumption whenever the device is ON in and will turn off when the plug is OFF
Value: 02 LED indicator will display the level of power consumption for 5 seconds only whenever the device is turned on or off
Value: 02 LED indicator will display the level of power consumption for 5 seconds only whenever the device is turned on or off
Value: 03 Always OFF