![EVA Logik ZW313 Скачать руководство пользователя страница 3](http://html.mh-extra.com/html/eva-logik/zw313/zw313_manual_2441427003.webp)
The Below listed Command Class are all supported the Security S2
COMMAND_CLASS_VERSION,
COMMAND_CLASS_SWITCH_MULTILEVEL,
COMMAND_CLASS_CONFIGURATION,
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_MANUFACTURER_SPECIFIC,
COMMAND_CLASS_DEVICE_RESET_LOCALLY,
COMMAND_CLASS_POWERLEVEL,
COMMAND_CLASS_SUPERVISION,
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
Z-Wave Configuration Parameters
1: Locally Button function
Paramter No: 1(0x01) Size:1 Byte Value: 00(default) Up Button ON,Down Button OFF
Value: 01 Up Button OFF,Down Button ON
2:Status LED Configuration
Paramter No: 2(0x02) Size:1 Byte Value: 00(default) Output ON,Led OFF.
Value: 01 OutputOFF,Led ON.
Value: 02 Always OFF
Value: 03 Always ON
3
:
Enable
Auto Turn-OFF Timer
Parameter=3
,
Size=1
,
Value=0 Auto Turn-OFF Timer
Disabled (default);
Value=1 Auto Turn-OFF Timer
Enabled
4:Count Down Configuration(Turn off the output by time)
Paramter No: 4(0x04) Size:2 Byte Value: xx xx Turn off Output
Value Scope :0----65535Minutes (default:00 00 no timer)
5
:
Enable
Auto Turn-ON Timer
Parameter=5
,
Size=1
,
Value=0 Auto Turn-ON Timer
Disabled (default);
Value=1 Auto Turn-ON Timer
Enabled
6:Count Down Configuration(Turn ON the output by time)
Paramter No: 6(0x06) Size:2 Byte Value: xx xx Turn ON Output
Value Scope :0----65535Minutes (default:00 00 no timer)
You may use the below configuration parameters to change settings of the corresponding functionality.
Value Scope :0----65535Minutes (default:00 00 no timer)
7:Association Setting Parameter
Paramter No: 7(0x07) Size:1 Byte Value: 00 None Value: 01 Local(Defaul)
Value: 02 3-way Value: 03 3-way&Local
Value: 04 z-wave hub Value: 05 z-wave hub&Local
Value: 06 z-wave hub&3-way Value: 07 z-wave hub&Local&3-way
Value: 08 Timer Value: 09 Timer&Local
Value: 10 Timer&3-way Value: 11 Timer&3-way&Local
Value: 12 Timer&z-wave hub Value: 13 Timer&z-wave hub&Local
Value: 14 Timer&z-wave hub&3-way Value: 15 All
8:Restores state after power failure
Paramter No: 8(0x08) Size:1 Byte Value: 00 Output OFF.
Value: 01 Output ON.
Value: 02 (default) The state before a power outage.
9:Dimmer Speed Parameter
Paramter No: 9(0x09) Size:1 Byte Value: 01(default) from 0x63 to 0x00 or from 0x00 to 0x63 need 1s
Value: 02 from 0x63 to 0x00 or from 0x00 to 0x63 need 2s
……………
Value: 99 from 0x63 to 0x00 or from 0x00 to 0x63 need 99s
10:Multilevel minimum value can be set(The minimum luminance value of the dimming)
Paramter No: 10(0x0A) Size:1 Byte Value: 00(default)
Value: 01
……………
Value: 99
11:Multilevel maxmum value can be set(The maxmum luminance value of the dimming)
Paramter No: 11(0x0B) Size:1 Byte Value: 00
Value: 01
……………
Value: 99 (default)
`
12:when switch is off and quickly press UPPER paddle 2 times, switch turns on to x brightness
Paramter No: 12(0x0C) Size:1 Byte Value: 00 Turn ON to 99
Value: 01
Notice
:when parameter 12 value is 0,the parameter 11 can not be set , and the value always is 0