background image

The Below listed Command Class are all supported the Security S2

COMMAND_CLASS_VERSION,
COMMAND_CLASS_SWITCH_MULTILEVEL,
COMMAND_CLASS_CONFIGURATION,
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_MANUFACTURER_SPECIFIC,
COMMAND_CLASS_DEVICE_RESET_LOCALLY,
COMMAND_CLASS_POWERLEVEL,
COMMAND_CLASS_SUPERVISION,
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2

Z-Wave Configuration Parameters

1: Locally Button function
      Paramter No: 1(0x01)     Size:1 Byte    Value: 00(default)   Up Button ON,Down Button OFF
                                                                        Value: 01                Up Button OFF,Down Button ON
2:Status LED Configuration
      Paramter No: 2(0x02)     Size:1 Byte    Value: 00(default)   Output ON,Led OFF.
                                                                        Value: 01                 OutputOFF,Led ON.
                                                                        Value: 02                Always OFF
                                                                        Value: 03                Always ON

3

Enable 

Auto Turn-OFF Timer

      Parameter=3

Size=1

Value=0    Auto Turn-OFF Timer

 Disabled (default); 

                                               Value=1    Auto Turn-OFF Timer

 Enabled

4:Count Down Configuration(Turn off the output by time)
      Paramter No: 4(0x04)     Size:2 Byte    Value: xx xx  Turn off Output
        Value Scope :0----65535Minutes  (default:00 00  no timer)

5

Enable 

Auto Turn-ON Timer

      Parameter=5

Size=1

Value=0    Auto Turn-ON Timer

 Disabled (default); 

                                               Value=1    Auto Turn-ON Timer

 Enabled

6:Count Down Configuration(Turn ON the output by time)
      Paramter No: 6(0x06)     Size:2 Byte    Value: xx xx  Turn ON Output
        Value Scope :0----65535Minutes  (default:00 00  no timer)

You may use the below configuration parameters to change settings of the corresponding functionality.

        Value Scope :0----65535Minutes  (default:00 00  no timer)
7:Association Setting Parameter
      Paramter No: 7(0x07)     Size:1 Byte    Value: 00    None                                      Value: 01    Local(Defaul)
                                                                        Value: 02    3-way                                    Value: 03    3-way&Local
                                                                        Value: 04    z-wave hub                           Value: 05    z-wave hub&Local
                                                                        Value: 06    z-wave hub&3-way              Value: 07    z-wave hub&Local&3-way
                                                                        Value: 08    Timer                                     Value: 09    Timer&Local
                                                                        Value: 10    Timer&3-way                        Value: 11   Timer&3-way&Local
                                                                        Value: 12    Timer&z-wave hub               Value: 13    Timer&z-wave hub&Local
                                                                        Value: 14    Timer&z-wave hub&3-way   Value: 15    All
8:Restores state after power failure
      Paramter No: 8(0x08)     Size:1 Byte    Value: 00                  Output OFF.
                                                                        Value: 01                  Output ON.
                                                                        Value: 02 (default)   The state before a power outage.
9:Dimmer Speed Parameter
      Paramter No: 9(0x09)     Size:1 Byte    Value: 01(default)     from 0x63 to 0x00 or from 0x00 to 0x63 need 1s
                                                                        Value: 02                  from 0x63 to 0x00 or from 0x00 to 0x63 need 2s
                                                                         ……………
                                                                        Value: 99                  from 0x63 to 0x00 or from 0x00 to 0x63 need 99s
10:Multilevel minimum  value can be set(The minimum luminance value of the dimming)
      Paramter No: 10(0x0A)     Size:1 Byte    Value: 00(default)          
                                                                          Value: 01                   
                                                                          ……………
                                                                         Value: 99                 
11:Multilevel maxmum value can be set(The maxmum   luminance value of the dimming)
      Paramter No: 11(0x0B)     Size:1 Byte    Value: 00         
                                                                          Value: 01                   
                                                                          ……………
                                                                         Value: 99    (default)              

`

12:when switch is off and quickly press UPPER paddle 2 times, switch turns on to x brightness
      Paramter No: 12(0x0C)     Size:1 Byte    Value: 00     Turn ON to 99    
                                                                          Value: 01                   

Notice

:when parameter 12 value is 0,the parameter 11 can not be set , and the value always is 0

Содержание ZW313

Страница 1: ...isation est soumise aux deux conditions suivantes 1 il ne doit pas provoquer d interférences gênantes et 2 il doit tolérer les interférences re ues notamment cellessusceptibles d en perturber le fonctionnement ZW313 Paddle Dimmer Switch Manual ZW313 Paddle Dimmer Switch WARRANTY Show Home Products warrants this product to be free from manufacturing defects for a period of two years from the origin...

Страница 2: ...ickly press UPPER paddle 2 times switch turns on to 100 brightness Function 6 Press and hold the up or down button for 10 seconds to restore the device to the factory Led Indicate Function 1 Flash three times When configuration parameter succeed LED flash three times 2 quickly flash When inclusion or exclusion or reset LED will quickly flash till operate complete Z Wave Remote Control ADD or Remov...

Страница 3: ...imer You may use the below configuration parameters to change settings of the corresponding functionality Value Scope 0 65535Minutes default 00 00 no timer 7 Association Setting Parameter Paramter No 7 0x07 Size 1 Byte Value 00 None Value 01 Local Defaul Value 02 3 way Value 03 3 way Local Value 04 z wave hub Value 05 z wave hub Local Value 06 z wave hub 3 way Value 07 z wave hub Local 3 way Value...

Страница 4: ...ons or releases notifications ZW313 will auto report Association group_2 basic set command command On 0xFF or Off 0x00 to its associated group Restoring Factory Defaults ZW313 is removed from the network and will be restored to the factory setting All Configuration Parameters values and Association information will be restored to factory default settings and excluded from the network Remark All th...

Отзывы: