background image

Introduction:

The ZW313 is a Z-Wave enabled device and is fully compatible with any Z-Wave Plus enabled network.

around obstacles and radio dead spots to ensure that the signal is received at its intended destination.

ZW313 is a security enabled Z-Wave plus device. A security Enabled Z-Wave Plus Controller must be used in order to fully utilize the product.

Key Features:

 ---Remote ON/OFF control via the Z-Wave controller
 ---Manual ON/OFF control with the front panel push button
 ---Support Association Group and Auto Report switch status
 ---Support firmware upgrades via Over-the-air (need Gateways support)

Product Overview:

A.   Up Push button

B.   Down Push button

C.   Load1 (Black) 

D.   Lin (Black) - Line in

E.   Nin (White) - Nutral in

F.   Load2 (Black)  

ZW313 Installation Wiring Diagram

Key function description

  Function 1:    Press the up or down button to turn the output ON or OFF
  Function 2:    Hold Dimmer Up or Dimmer Down

Each module is designed to act as a repeater,which will re-transmit a radio frequency (RF) signal by routing the signal

A

B

F

  Function 2:    Hold Dimmer Up or Dimmer Down
  Function 3:    Press the up or down button three times quickly to ADD and REMOVE
  Function 4:    Press the up or down button six times quickly to change Status LED Configuration
  Function 5:    When switch is off and quickly press UPPER paddle 2 times, switch turns on to 100% brightness
  Function 6:    Press and hold the up or down button for 10 seconds to restore the device to the factory

Led Indicate Function

1:Flash three times
     When configuration parameter succeed LED flash three times
2:quickly flash

  

    When inclusion or exclusion or reset, LED will quickly flash till operate complete

Z-Wave Remote Control

ADD or Remove the ZW313 from the existing Z-Wave home control network with your primary controller.
 ---Refer to your primary controller instructions to process the inclusion / exclusion setup procedure.

Include ZW313 to/from a Z-Wave Gateway with supporting Security.The ZW313 can support the Primary Controller that implemented the security S2.
Notice: Including a node ID allocated by Z-WaveTM Controller means “Add” or “Inclusion”. Excluding a node ID allocated by 
Z-WaveTM Controller means “Remove” or “Exclusion”.

z-wave protocol Command Class Node Info 

COMMAND_CLASS_ZWAVEPLUS_INFO,
COMMAND_CLASS_SWITCH_MULTILEVEL,
COMMAND_CLASS_CONFIGURATION,
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_TRANSPORT_SERVICE_V2,
COMMAND_CLASS_VERSION,
COMMAND_CLASS_MANUFACTURER_SPECIFIC,
COMMAND_CLASS_DEVICE_RESET_LOCALLY,
COMMAND_CLASS_POWERLEVEL,
COMMAND_CLASS_SECURITY_2,
COMMAND_CLASS_SUPERVISION,
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2

 ---When prompted by your primary controller, click the Up or Down button three times in one second.

Содержание ZW313

Страница 1: ...isation est soumise aux deux conditions suivantes 1 il ne doit pas provoquer d interférences gênantes et 2 il doit tolérer les interférences re ues notamment cellessusceptibles d en perturber le fonctionnement ZW313 Paddle Dimmer Switch Manual ZW313 Paddle Dimmer Switch WARRANTY Show Home Products warrants this product to be free from manufacturing defects for a period of two years from the origin...

Страница 2: ...ickly press UPPER paddle 2 times switch turns on to 100 brightness Function 6 Press and hold the up or down button for 10 seconds to restore the device to the factory Led Indicate Function 1 Flash three times When configuration parameter succeed LED flash three times 2 quickly flash When inclusion or exclusion or reset LED will quickly flash till operate complete Z Wave Remote Control ADD or Remov...

Страница 3: ...imer You may use the below configuration parameters to change settings of the corresponding functionality Value Scope 0 65535Minutes default 00 00 no timer 7 Association Setting Parameter Paramter No 7 0x07 Size 1 Byte Value 00 None Value 01 Local Defaul Value 02 3 way Value 03 3 way Local Value 04 z wave hub Value 05 z wave hub Local Value 06 z wave hub 3 way Value 07 z wave hub Local 3 way Value...

Страница 4: ...ons or releases notifications ZW313 will auto report Association group_2 basic set command command On 0xFF or Off 0x00 to its associated group Restoring Factory Defaults ZW313 is removed from the network and will be restored to the factory setting All Configuration Parameters values and Association information will be restored to factory default settings and excluded from the network Remark All th...

Отзывы: