background image

Page 4

GENIUS LCD 100

2. SAFETY INSTRUCTIONS

WARNING!

 This signal word indicates a hazard with a medium degree of risk which, if not avoided, may result in death 

or serious injury.

NOTE!

 This signal word warns of possible material damage.

SAFETY INSTRUCTIONS:

- GENIUS LCD100 is designed for use in buildings.

- Operate GENIUS LCD100 only as described in the user manual.

- GENIUS LCD100 should only be put to use in a dry and dust-free place, away from direct sunlight.

- Do not keep using the device when there is obvious damage.

- GENIUS LCD100 may not be rebuilt, modified or opened.

WARNING! RISK OF EXPLOSION!

Improper handling of batteries can lead to explosion.

- Do not heat batteries and do not throw batteries into an open fires.

- Do not place batteries in direct sunlight.

- Protect batteries from excessive heat.

- Do not short-circuit the batteries.

- Never attempt to charge non-rechargeable batteries.

- Never disassemble batteries.

- Do not use new and used batteries together.

- Observe the correct polarity (+/-) when inserting the batteries.

- Before inserting the batteries, clean the batteries and the contacts in the thermostat.

WARNING! RISK OF ACID BURNS!

Leaking battery acid can lead to burns.

- Avoid contact of battery acid with skin, eyes and mucous membranes.

-  In case of contact with battery acid, rinse the affected areas immediately with plenty of clear water and consult a 

doctor.

WARNING! RISK OF INJURY!

When children play with the thermostat or packaging, they might swallow small parts and suffocate.

- Do not let children play with the thermostat or packaging.

- Keep batteries away from children. Seek medical attention immediately if batteries are swallowed.

WARNING! SENSITIVITY TO LIGHT!

Some people may have epileptic seizures if they are exposed to certain light effects, even if no previous incidents are 

known.

Содержание GENIUS LCD100

Страница 1: ...Eurotronic Technology GmbH S dweg 1 36396 Steinau Ulmbach Germany www eurotronic org THE INGENIOUS ENERGY SAVING CONTROLLER GENIUS INSTALLATION OPERATION GUIDE GENIUS LCD100...

Страница 2: ...App 13 8 1 Settings App 13 8 2 Temperature App 14 8 3 Heating profile App 14 8 4 Holiday App 15 8 5 Support App 15 9 Basic operating modes 16 17 10 Further functions 18 11 Cleaning and storage 18 12 T...

Страница 3: ...LR6 2x Batteries AA LR6 Screw for adapter GENIUS energy saving thermostat When using the RAV adapter you need the RAV Pin for the extension of the valve stem RAV RA RAVL RAV Pin NOTE The following fig...

Страница 4: ...at Do not short circuit the batteries Never attempt to charge non rechargeable batteries Never disassemble batteries Do not use new and used batteries together Observe the correct polarity when insert...

Страница 5: ...to operation quickly and easily GENIUS LCD 100 GENIUS LCD 100 is an energy saving controller for radiators equipped with Fast Link technology for modern and simple operation It automatically regulates...

Страница 6: ...g dismounting mode please only screw or unscrew the energy saving controller onto the valve in this mode p 9 ADAPTATION Start of a new adaptation for valve adjustment p 11 RESET Resetting the controll...

Страница 7: ...successful Fast Link was not successful Window open detection active Anti freeze protection function active Adaptation the animation is displayed until the adaptation is complete Holiday function OK S...

Страница 8: ...ear date and time can now be set one after the other Set the year with PLUS MINUS Confirm with OK SET Set the month with PLUS MINUS Confirm with OK SET Set the day with PLUS MINUS Confirm with OK SET...

Страница 9: ...e fastening and pull it off the valve ill 3 2 If necessary select a suitable adapter and mount it on the valve ill 4 3 Screw the thermostat onto the valve or adapter by turning the union nut clockwise...

Страница 10: ...and Danfoss RAVL are included For the following valves an adapter is required Herz M28 x 1 5 mm Comap M28 x 1 5 mm Vaillant 30 5 mm Oventrop M30 x 1 0 mm Meges M38 x 1 5 mm Ondal M38 x 1 5 mm Giacomin...

Страница 11: ...shows the setpoint tempera ture If a new adaptation is necessary e g if your radiator does not become cold in the OFF position please select ADAPTATION in the menu Confirm with OK SET and start the ad...

Страница 12: ...NOTE To ensure trouble free transmission set the brightness of your display to the highest level No energy saving mode or similar must be activated 1 Remove the battery cover ill 9 2 Select FASTLINK f...

Страница 13: ...remain closed By activating the child lock manual operation on the controller is blocked The symbol is shown in the display If you activate the Summer winter time toggle switch the time changeover is...

Страница 14: ...Temperature you may set your comfort and economy temperatures The temperature shown above is the one currently being set Here you can create a heating profile for the whole week Here you can create di...

Страница 15: ...the room tempe rature for the duration of your absence After you have created your holiday profile transmit it via Fast Link The menu item Holiday allows you to create a holiday profile for the time...

Страница 16: ...sence you can determine a freely selectable temperature After the set time has elapsed the programme you have set will automatically run again To set the holiday mode press MENU Press PLUS MINUS to se...

Страница 17: ...rday D1 7 same programme Monday to Sunday If days are not programmed the factory settings remain active To set and save an individual programme press MENU Use PLUS MINUS to select the HEATING PROFILE...

Страница 18: ...tion of your controller you can lock the GENIUS LCD 100 Press and hold the OK SET and MENU buttons simultaneously for approx 3 seconds until the symbol appears on the display If you press this combina...

Страница 19: ...r has not been applied to the valve Insert thrust piece Press the OK button or perform adaptation of the device by removing and reinserting the batte ries The endless thread now turns and tightens the...

Страница 20: ...s W x H x D 56 x 68 x 89 mm Weight 149 7 g incl batteries Degree of protection IP20 Degree of pollution 2 Technical modifications are subject to change All descriptions for compatibility are without e...

Страница 21: ...y Eurotronic Technology GmbH hereby declares that the GENIUS LCD 100 radiator thermostat complies with all applicable European Economic Area regulations of Directive 2014 53 EU The full text of the EU...

Страница 22: ...Eurotronic Technology GmbH S dweg 1 36396 Steinau Ulmbach Germany www eurotronic org Stand 17 05 19...

Отзывы: