Page 64/72
October 2019
W11E | Operation manual
6.5.2
Analog Inputs
Wiring
All Analog Inputs are +5/12V pull down, the recommend resistance range of external potentiometer is 5÷10k
Ω
.
Potentiometer connected to Analog Input
Analog Inputs on Controller
Pin
Meaning
Pin
Meaning
K1 - 18
I/O Ground
K2 - 1
+5V Out
K1 - 21
+12V Out
K2 - 12
Analog Input 1
K2 - 13
Analog Input 2
K2 - 19
Analog Input 3
K2 - 20
Analog Input 4
K2 - 21
Analog Input 5
K2 - 22
Analog Input 6