PC300 User Guide

HA 026773

Page 2 of 4

Issue 1.3 June 2000

Installation

Dimensional Details  (mm)

Location

The Power Supply Unit resides in the first ’slot’ in every rack.  The second ’slot’ contains the Local
Control Module.

I/O module addresses

Configuration is made simple - there is no requirement to configure jumpers or switches to set I/O module
addresses.  The module address is read directly from the backplane.

Compatability

The PC300 is directly compatible with and a subset of the PC3000.  The two products share I/0 cards,
programming tools.and instruction manuals.

Manuals

PC3000 instruction manuals are used for the PC300.

219

316

44

53

30

42

120

193

166

44

16

182

Alternate Bracket Position

94

203

Earth Connection

M8

338

Allow 15mm clearance
above bracket for fitting

Note:

5 THK.

Содержание PC300

Страница 1: ...th 203 mm inc mounting brackets Width 316 mm Mounting Bulkhead mounting Casing Robust Metal case to IP20 Module capacity 2 single with I O slots Ventilation Space 25mm free space above and below Environmental Operating Temperature 0 to 50o C Storage Temperature 20 to 70o C Relative Humidity 5 to 95 non condensing Weight 5 25 Kg Weight support brackets 0 4 Kg each EMC Emissions EN50081 2 1994 Immun...

Страница 2: ...nt to configure jumpers or switches to set I O module addresses The module address is read directly from the backplane Compatability The PC300 is directly compatible with and a subset of the PC3000 The two products share I 0 cards programming tools and instruction manuals Manuals PC3000 instruction manuals are used for the PC300 219 316 44 53 30 42 120 193 166 44 16 182 Alternate Bracket Position ...

Страница 3: ...sor status run and fault system diagnostic functions and communication channel activity are provided System and IOC status LED s F Fault R Run Diagnostic LED s Consult PC3000 Hardware Reference Manual for details Communication LED s A B C Serial channel communication activity D Extension rack communication activity 3RZHU 6XSSO 8QLW 368 nc nc nc nc C Common N O Normally Open Health N C Normally Clo...

Страница 4: ...ecome disconnected should excess tension be applied to the mains cable 3 It is recommended that crimps be used to terminate the wires before they are inserted into the terminal blocks 4 The Mains supply fuse within the Power supply unit is replaceable and should only be replaced with a fuse of the same type and rating In no conditions should the fuse be replaced with one of a higher rating 5 Whene...

Отзывы: