EUROSTER 11E USER MANUAL

1

EUROSTER 11E 

CENTRAL HEATING/UTILITY HOT WATER SYSTEM PUMP CONTROLLER

MANUFACTURER: P.H.P.U. AS, Polanka 8a/3, 61-131 Poznań, POLAND

1

INTRODUCTION

Carefully study this user manual to learn how to correctly operate the EUROSTER 11E central 

heating/utility hot water system pump controller.

2

FIELD OF APPLICATION

EUROSTER 11E 

is a modern microprocessor-based controller used to control central heating 

(CH) system pump or utility hot water (UHW) system pump.
The  

EUROSTER   11E

  controller   features   the   ANTY   STOP 

function that prevents idle pump rotors against seizing. Once 
the   heating   season   is   over,   every   14   days   the   function 

automatically  turns ON the  pumps for 30 seconds. To  that 
end the controller must be left powered up.

3

VISIBLE CONTROLLER ELEMENTS 

1. 230 VAC~ mains input 

2. 230 VAC~ power supply to pump 
3. Input for temperature sensor cable 

4. Mains switch 
5. LCD display

6. Knob

4

INSTALLATION

Hazardous voltages may be present inside the controller and on its cables. 

Therefore it is expressly forbidden to install the device prior to disconnecting 
its mains power supply. Only qualified technicians may install the controller. 

Do not install any devices showing signs of any mechanical damage.

The procedure:

a) Mount the controller:

using a pair of supplied nylon nail-it fasteners (anchors) mount the controller box on a 

Содержание 11E

Страница 1: ...gainst seizing Once the heating season is over every 14 days the function automatically turns ON the pumps for 30 seconds To that end the controller must be left powered up 3 VISIBLE CONTROLLER ELEMEN...

Страница 2: ...power supply cable into a 230V 50Hz mains socket equipped with a grounding pin The controller must not be installed in a place where the ambient temperature may exceed 40 C 5 CONTROLLER DISPLAY Eleme...

Страница 3: ...s to change the mode Set 1 has been complied for layouts in which CH system pump is controlled Set 2 has been complied for layouts in which UHW pump is controlled Proceed as follows to restore factory...

Страница 4: ...0 80 80 C Pump hysteresis 4 4 2 2 10 10 C Temperature sensor correction 0 0 5 5 5 5 C Pump manual operation test as calculated by the controller as calculated by the controller 0 OFF 0 OFF 1 ON 1 ON 9...

Страница 5: ...d a odwo ania Check pump connection d Controller knob operates erratically Pulse generator failure Have the controller serviced 12 COMPATIBILITY WITH STANDARDS CERTIFICATES The EUROSTER 11E controller...

Страница 6: ...operate the system is shown Central heating pump control mode 1 EUROSTER 11E controller 2 CH boiler 3 Heat source temperature sensor 4 CH pump 5 Radiator heat load Utility hot water pump control mode...

Страница 7: ...arranty terms 1 Warranty is valid for 24 months from the controller sale date 2 Warranty is valid exclusively on the territory of Poland 3 Claimed controller together with this warranty certificate mu...