I

NTRODUCTION

 

Thank you for selecting EUROPEAN TOUCH, the leading designer, manufacturer, and marketer of 
pedicure spas in North America.  The Forte and Altera pedicure spas (herein referred to as

 

pedicure 

spa) are innovative whirlpool pedicure spas that have been designed to serve you dependably for many 
years.  Please take time to thoroughly read this entire manual before installation and use.  If you have 
any problems or have questions regarding your pedicure spa, please contact EUROPEAN TOUCH’s 
Technical Support Department at 

1-800-626-6912,

 Monday through Friday 8 AM to 5 PM CST.  After 

hours calls are recorded and attended to the next business day. 
 

I

MPORTANT 

R

EQUIREMENTS

 

EUROPEAN TOUCH requires that you contact a local, licensed plumber and licensed electrician to 
install your new pedicure spa.  Installation must be in compliance with all your local and state building 
codes.  Your pedicure spa cannot operate efficiently or safely unless it is provided with adequate 
electrical power, sufficient water pressure, proper water temperature, and required drainage 
capabilities.  Contact your local building inspector for information and local code compliance 
procedures that need to be followed when having your pedicure spa installed.  Subsequent inspections 
and approvals that may be required are the responsibility of the purchaser. 

(See limited warranty 

regarding incidental or consequential exclusions – page 2). 

 

P

RECAUTIONS

 

  Do not stand in the basin of the pedicure spa! 

  Excessive water temperature is dangerous and should be checked before use.  

Maximum operating water temperature should not exceed 105

°

 F (41

°

 C) and the 

maximum supply water temperature should not exceed 150

°

 F (66

°

 C). 

  Always enter and exit the pedicure spa slowly and carefully. 

  Close side arms rests before operating the chair seat movement. 

  Never bring or operate any electrical devices into or near the pedicure spa. 

  This pedicure spa has a weight capacity of 250 pounds (113.4kg). 

 

H

EALTH 

R

ISK 

W

ARNING

 

Individuals whose feet or legs are inflamed or have open wounds should not be allowed to use 
the pedicure spa at any time.  Nail technicians should advise clients to consult their physician 
before using the pedicure spa if there is any sign of fungal infection, swelling, fracture, or 
persistent pain.  In some cases diabetics may experience improved circulation in their feet, but 
should first consult their physician prior to receiving a pedicure

.  If the client experiences any 

pain or discomfort, immediately discontinue the use of the pedicure spa. 
 
 
Your client’s massage and pedicure spa experience should be pleasant and comfortable. 

Содержание ALTERA SPA

Страница 1: ...The World s Finest Pedicure Spas OWNER S MANUAL FORTE SPA ALTERA SPA CRYSTAL CLEAN PIPE FREE TRADITIONAL WHIRLPOOL...

Страница 2: ...ponents or part if altered or modified in any way To any expenses incurred by the Customer or any third party including labor or material during investigation removal or reinstallation of the Pedicure...

Страница 3: ...le for any other obligations or liabilities including but not limited to obligations or liabilities arising out of breach of contract or warranty negligence or other tort or any theory of strict liabi...

Страница 4: ...Rated 220 240VAC 50Hz 7 5A To the following standard s EN60335 1 2002 EN60335 2 32 2002 EN 55014 1 Generic 2001 EN 55014 2 Generic 2003 EN61000 4 2 Criteria C 2001 EN61000 4 3 2002 EN61000 4 4 1995 E...

Страница 5: ...6 6912 Page 5 of 24 OWNERS MANUAL For Whirlpool Pedicure Spa Models FORTE and ALTERA IMPORTANT INFORMATION Serial Number W O Number Installed by Installation Date Serial Number W O Number Note Vietnam...

Страница 6: ...AL WHIRLPOOL WITH JETS 10 CRYSTAL CLEAN PIPE FREE 11 TRADITIONAL WHIRLPOOL WITH JETS 12 SPECIFICATIONS 13 ATTACHING THE SEAT BACK 14 UNPACKING THE CUSHIONS 15 REMOTE CONTROL CONFIGURATIONS 15 ATTACHIN...

Страница 7: ...edures that need to be followed when having your pedicure spa installed Subsequent inspections and approvals that may be required are the responsibility of the purchaser See limited warranty regarding...

Страница 8: ...comply with all plumbing and electrical codes A licensed plumber and licensed electrician must complete the applicable connections of the pedicure spa LOCATION AND SUPPORT Select a level location The...

Страница 9: ...A112 18 1M and CSA B125 ANSI ASME A112 18 3M Performance Requirements for Backflow Protection Devices and Systems in Plumbing Fixture Fittings is applicable to plumbing fixture fittings with outlets...

Страница 10: ...Document ID 06080001 Rev L Technical Support 800 626 6912 Page 10 of 24 DIMENSIONAL DRAWINGS CRYSTAL CLEAN PIPE FREE AND TRADITIONAL WHIRLPOOL WITH JETS...

Страница 11: ...Document ID 06080001 Rev L Technical Support 800 626 6912 Page 11 of 24 CRYSTAL CLEAN PIPE FREE...

Страница 12: ...Document ID 06080001 Rev L Technical Support 800 626 6912 Page 12 of 24 TRADITIONAL WHIRLPOOL WITH JETS...

Страница 13: ...rotected Caution Pedicure spa must be installed by a licensed electrician and a licensed plumber conforming to all local and national electrical codes Construction Linear Low Density Polyethylene LLDP...

Страница 14: ...on the back of the chair Step 1 Remove the hitch and clevis pins located on the seat back mounting bracket on the back of the chair Step 2 Slide the seat bracket into the black end on the linear actua...

Страница 15: ...Move Seat Bottom Slide Forward or Backward Indicates that Vibrate Feature is Activated Type of Vibrating Massage Surge Steady Pulse Wave Increase or Decrease Intensity of vibrating massage Forte Alte...

Страница 16: ...the chair bottom Make sure that the cushion is centered on the chair bottom The arms should be able to close without cushion interference Step 5 FORTE ONLY The remote control and power supply cord ar...

Страница 17: ...sive foam It has been determined that products containing non dissolving abrasives such as sand and sea salts will not harm the internal component structure of your pedicure spa as long as the entire...

Страница 18: ...ol depress the On Off button labeled Jets NOTE An indicator light on the Jets button flashes when the footplate is improperly installed or the basin contains no water As a result the whirlpool will no...

Страница 19: ...placing the footplate carefully align the mounting studs with the mounting holes Tighten each knob until snug Be careful not to over tighten as this can damage the Knobs After Last Pedicure of the Day...

Страница 20: ...e Jet heads should not be positioned directly at the suction cover Doing so will create a noisy gurgling sound as air is being forced directly into water pipes Turn off the whirlpool jets by turning t...

Страница 21: ...ponent with low sudsing soap or detergent using a soft brush Disinfect the components as well as the areas behind them with an EPA registered disinfectant Follow your state board requirements for disi...

Страница 22: ...If the adjustment cover is hard to turn slightly loosen the jet nozzle nut Step 5 Reverse steps to reassemble REMOVAL REPLACING SUCTION COVER Tools required Philips head screwdriver Check your state...

Страница 23: ...own for cleaning reference Step 2 To remove the handle adapter place Phillips head screwdriver into upper slot to reach screw as shown in picture above Unscrew and then pull adapter forward Step 4 Pic...

Страница 24: ...EUROPEAN TOUCH 8301 W Parkland Court Milwaukee WI 53223 Phone Number 414 357 7016 Toll Free 800 626 6912 Fax 414 357 6360 Web Site www europeantouch com Email info europeantouch com...

Отзывы: