![European Home DV 38 Скачать руководство пользователя страница 15](http://html.mh-extra.com/html/european-home/dv-38/dv-38_installation-operation-and-maintenance-manual_2439774015.webp)
Page 15
DV 38 Gas Fireplace
Installation
Section 3-3-3: Heat Shields
installing a wall Mounted rHS8 Heat Shield
The RHS8 Heat Shield
CANNOT
be used
when the termination
is within 36" horizontal and 46" vertical from the fireplace or
directly off the rear of the fireplace
, as shown
Figure 19a
. The
RHS101 Heat Shield (
Figure 19c and 19d
)
MUST
be used within
the noted dimensions.
To install the RHS8, frame an opening in combustible
construction,
Figure 19
below. Slide the heat shield in place
over the vent pipe which attaches to the fireplace. After the
fireplace and vent pipe has been installed, clearances should
match the dimensions in
Figure 19
.
Figure 19.
RHS8 Installation. Install by sliding over vent pipe where it passes through
the combustible construction.
Figure 19c.
RHS101 Installation. Install by sliding outer section over vent pipe
where it passes through the combustible construction.
Figure 19d.
Heat Shield, after sliding the outer section in place.
Termination
Drywall / sheetrock
RHS101 Heat Shield, inner Section
RHS101 Heat Shield
Outer Section
Fireplace
installing a wall Mounted rHS101 Heat shield.
The RHS101 Heat shield
MUST
be used where the RHS8
Termination (
Figure 19 and 19a
)
CANNOT
be used.
Use the
RHS101 where any of the dimensions are within the parameters
shown,
Figure 19a.
To install the RHS101, Slide the Inner Section over the vent
pipe that will connect to the fireplace. Then fasten the vent
pipe to the back of the fireplace with a minimum of three
sheet metal screws.
Be sure to maintain the maximum 12"
fireplace clearance.
From the outside slide the RHS101 outer
section on see
Figure 19c
. To complete the installation fasten
the heat shield outer section and termination frame to the
structure
Figure 19d.
Figure 19a.
RHS8 Installation, minimum requirements.
RHS8 Heat Shield
1” Min. Both sides Typical
2” Min.
1” Min.
Combustible Framing
12” max
Combustible
framing
Termination
Drywall / sheetrock
RHS101 Heat Shield, inner Section
RHS101 Heat Shield
Outer Section
Fireplace
Vent pipe, from fireplace
RHS8 Heat
Shield
36” Min
46” Min.
PTO Termination