MADE IN MAL
230Va.c. 4.5kW 50/60Hz
ELECTRICAL LOADING
TYPE
WATER CONNECTION
DIMENSIONS
155mm x 83mm x 248mm
WEIGHT
1/2’’ BSP MULTI POINT SYSTEM
1.5 Kg
ELECTRONIC POWER CONTROL
Min. INLET WATER PRESSURE
Max. INLET WATER PRESSURE
0.1 Bar ( 10kPa)
6.0 Bar ( 0.6MPa)
E
N
L
G
N1
T2
TRIAC
Manual Reset
Thermal
Cut-Out
( 2Poles)
Heater
Tank
Power ON/OFF
Temp. Control
RC CB/ POWER
Turbine Flow Switch
TR FS
Thermistor
Inlet
Outlet
ELECTRICAL SPECIFICATION
WIRING DIAGRAM
MAINTENANCE
MAINTENANCE
CLEAN THE FILTER REGULARLY
Read the section ‘ SAFETY INFORMATION ’
If any abnormal condiiton to the water heater, switch OFF the mains
for repair service. Special skill is required for repairing. NEVER try to repair the unit by yourself.
CLEANING PRECAUTION !
Do not use thinner, alcohol, petrol or any other organic solutions to clean the set. Use only damped
cloth with mild detergent.
supply and contact sales agent
Clean the Mesh Filter regularly to prevent blockage. When carrying out any work,
Note : Water heater must be permanently connected to the electricity supply through a Manual Reset
Thermal Cut Out (2 Poles) having a contact sepration of at least 3mm in all poles incorporated in
the circuit.