EN
110
G30 28-30mbar 4,8 kW 345 g/h II2H3B/P BG
Class:3
G20 20
mbar
G30 28-30
mbar
LARGE BURNER
DIA. of INJECTOR (1/100mm)
115
85
NOMINAL RATING (KW)
3
3
CONSUMPTION
285,7 g/h
218,1 g/h
SMALL BURNER
DIA. of INJECTOR (1/100mm)
97
65
NOMINAL RATING (KW) 9
1,75
1,75
CONSUMPTION
166,7 l/h
127,2 g/h
6.2 Transport
If you need to transport the product, use
the original product packaging and car-
ry it using its original case. Follow the
transport signs on the packaging. Tape
all independent parts to the product to
prevent damaging the product during
transport.
If you do not have the original packag-
ing, prepare a carriage box so that the
appliance, especially the external sur-
faces of the product, is protected against
external threats.
7. TECHNICAL SPECIFI-
CATIONS
7.1. Injector table
Problem
Possible Cause
Solution
Burner is not igniting
or only partially
lighting.
Burner parts may not be clean or dry.
Ensure that parts of the appliance are
dry and clean.
Burner sounds noisy.
-
This is normal. The noise may reduce as
they heat up.
Noise
-
It is normal for some metal parts on the
cooker to produce noise when in use.