background image

 

00086063.DOC, Version 2.2 

13/15

INSTALLATION 

 

 

 
The motor must only be installed in an absolutely horizontal position at a vibration-free, oscilation-free and 
fire-resistant location. By using a water-level, make sure that the motor is installed absolutely horizontally 
and that the motor axle points exactly to the bottom. 
 
If the motor and the mirror ball are to be operated above persons, additional risks arise. A hazard analysis 
based on the location and application must be performed in order to ensure dimensioning and measures for 
a safe operation. Both the motor and the mirror ball meet the professional association safety regulations 
regarding safety and operation. 
 
The installation of the mirror ball has to be built and constructed in a way that it can hold 10 times the weight 
for 1 hour without any harming deformation. 

 

The installation must always be secured with a secondary safety attachment. This secondary safety attach-
ment must be constructed in a way that no part of the installation can fall down if the main attachment fails. 

 

When rigging, derigging or servicing the fixture staying in the area below the installation place, on bridges, 
under high working places and other endangered areas is forbidden. 

 

The operator has to make sure that safety-relating and machine-technical installations are approved by an 
expert before taking into operation for the first time and after changes before taking into operation another 
time. 
The operator has to make sure that safety-relating and machine-technical installations are approved by an 
expert after every four year in the course of an acceptance test. 

 

The operator has to make sure that safety-relating and machine-technical installations are approved by a 
skilled person once a year. 
 

Attachment 

The rotary motor should ideally be installed outside areas where persons may walk by or be seated. 
 
IMPORTANT! OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE, including (but not limited to) 
calculating working load limits, installation material being used, and periodic safety inspection of all 
installation material and the mirror ball. If you lack these qualifications, do not attempt the installation 
yourself, but instead use a professional structural rigger. Improper installation can result in bodily injury 
and/or damage to property.  
 
The motor and the mirror ball have to be installed out of the reach of people. 
 
If the motor shall be lowered from the ceiling or high joists, professional trussing systems have to be used. 
The motor must never be fixed swinging freely in the room. 
 

Caution:

 Mirror balls may cause severe injuries when crashing down! If you have doubts concerning the 

safety of a possible installation, do NOT install the motor! 
 
Before attaching the device, make sure that the installation area can hold a minimum point load of 10 times 
the device's load (e.g. maximum load 3 kg - point load 30 kg). 
 
The mirror ball motor must always be installed via all fixation holes. Do only use appropriate screws and 
make sure that the screws are properly connected with the ground. 
 
The durability of the installation depends very much on the material used at the installation area (building 
material) such as wood, concrete, gas concrete, brick etc. This is why the fixing material must be chosen to 
suit the wall material. Always ask a specialist for the correct plug/screw combination indicating the maximum 
load and the building material. 

Содержание MD-3050

Страница 1: ...n interdit Prohibida toda reproducci n F r weiteren Gebrauch aufbewahren Keep this manual for future needs Gardez ce mode d emploi pour des utilisations ult rieures Guarde este manual para posteriores...

Страница 2: ...TRODUCTION 10 SAFETY INSTRUCTIONS 10 OPERATING DETERMINATIONS 11 DESCRIPTION OF THE DEVICE 12 Features 12 Safety features 12 Overview 12 INSTALLATION 13 Attachment 13 Connection with the mains 14 CLEA...

Страница 3: ...ende Hinweise beachten sind wir sicher dass Sie lange Zeit Freude an Ihrem Kauf haben werden Nehmen Sie den Motor aus der Verpackung SICHERHEITSHINWEISE ACHTUNG Seien Sie besonders vorsichtig beim Umg...

Страница 4: ...Spritzwasser Regen Feuchtigkeit oder Nebel zu rechnen ist Feuchtigkeit oder sehr hohe Luftfeuchtigkeit kann die Isolation reduzieren und zu t dlichen Stromschl gen f hren Beim Einsatz von Nebelger ten...

Страница 5: ...der ersten Inbetriebnahme muss die Einrichtung durch einen Sachverst ndigen gepr ft werden Sicherheitsmerkmale Robuste Bauweise mit Stahlgeh use f r lange Laufzeiten Hohe Stabilit t durch massive Moto...

Страница 6: ...ebnahme durch Sachverst ndige gepr ft werden Der Unternehmer hat daf r zu sorgen dass sicherheitstechnische und maschinentechnische Einrichtungen mindestens alle vier Jahre durch einen Sachverst ndige...

Страница 7: ...lmutter gut fest Sichern Sie die Spiegelkugel bei berkopfmontage immer mit einer Sicherungskette die mindestens f r das 12 fache Gewicht der Installation ausgelegt ist Die Sicherungskette muss etwas l...

Страница 8: ...Umfang der Abnahmepr fung gepr ft werden Der Unternehmer hat daf r zu sorgen dass sicherheitstechnische und maschinentechnische Einrichtungen mindestens einmal j hrlich durch einen Sachkundigen gepr...

Страница 9: ...h 450 kg Max Last BGV C1 8 fach 225 kg Max Last BGV C1 10 fach 180 kg Max Last BGV C1 12 fach 150 kg Max Spiegelkugeldurchmesser 150 cm EUROLITE Rotationsgeschwindigkeit ca 1 U Min Ma e LxBxH 280 x 24...

Страница 10: ...that you will enjoy this device for a long period of time Unpack your motor SAFETY INSTRUCTIONS CAUTION Be careful with your operations With a dangerous voltage you can suffer a dangerous electric sh...

Страница 11: ...isture or fog may harm the device Moisture or very high humidity can reduce the insulation and lead to mortal electrical shocks When using smoke machines make sure that the device is never exposed to...

Страница 12: ...re taking into operation for the first time the installation has to be approved by an expert Safety features Rugged construction with steel housing for long operation High stability due to massive mot...

Страница 13: ...f an acceptance test The operator has to make sure that safety relating and machine technical installations are approved by a skilled person once a year Attachment The rotary motor should ideally be i...

Страница 14: ...strain of a crash or which is defective must not be used again There must never hang a mirror ball or other load at the safety eyelet Loads must only be hanged at the quick link of the installation e...

Страница 15: ...be any deformations on housings fixations and installation spots ceiling suspension trussing 3 Mechanically moved parts like axles eyes and others must not show any traces of wearing e g material abra...