00094572.DOC, Version 1.0
17/18
happen that the stand-by lamp turns off (the remote control lamp lights up red) and the smoke emission
stops. In this case the device is heating up again and will be ready to operate in approx. 1-2 min. (the remote
control lamp lights up green again) This process guarantees an appropriate vaporization temperature and
the best smoke emission possible. The temperature is regulated by a high quality thermostat.
CAUTION: The escape nozzle will heat up during operation. Therefore do not touch the nozzle until it
has cooled down completely.
For the light effect, turn the device on via the EFFECT Power switch.
The LEDs in red, green and blue move backwards and forwards in clockwise direction (180°).
CLEANING AND MAINTENANCE
Disconnect from mains before starting maintenance operation!
DANGER TO LIFE!
We recommend a frequent cleaning of the device. Please use a soft lint-free and moistened cloth. Never use
alcohol or solvents!
Clean the escape nozzle frequently from smoke fluid residues.
Cleaning the heating element
The heating element should regularly be cleaned every 30 operational hours in order to avoid clogging. Use
smoke machine cleaner available at your dealer.
Procedure:
Fill cleaner into empty tank. Run the machine several times in a well-ventilated room only. The number of
repetitions depends on the pollution level of the vaporizing elements. After use clean all remaining cleaner
and rinse the tank thoroughly.
The EUROLITE smoke fluids we recommend are non-hazardous to the environment and can be disposed of
via the sewage system.
There are no serviceable parts inside the device except for the fuse. Maintenance and service operations are
only to be carried out by authorized dealers.
Replacing the fuse
If the fine-wire fuse of the device fuses, only replace the fuse by a fuse of same type and rating.
Before replacing the fuse, unplug mains lead.
Procedure:
Step 1:
Open the fuseholder on the rearpanel with a fitting screwdriver.
Step 2:
Remove the old fuse from the fuseholder.
Step 3:
Install the new fuse in the fuseholder.
Step 4:
Replace the fuseholder in the housing.
Should you need any spare parts, please use genuine parts.
If the power supply cable of this device will be damaged, it has to be replaced by a special power supply
cable available at your dealer.
If defective, please dispose of the unusable device in accordance with the current legal regulations.