Contact with the hot surfaces of the boiler can lead to burns. Wait until the boiler has cooled
down before touching uninsulated components.
Danger of asphyxiation and explosion from carbon monoxide.
When the boiler is in operation,
carbon monoxide escaping from opened cleaning or inspection hatches can pose a danger of
asphyxiation or explosions. Do not leave these open any longer than necessary.
Opening doors and lids to hot combustion residues can pose the danger of fires. Keep the
openings closed during operation, and when performing cleaning work, allow the combustion
residue to cool down before you place them in a fireproof container.
The boiler weighs over 750kg. If the boiler is dropped during transport, persons can be
seriously injured and the boiler can be damaged. Make sure that you use appropriate lifting gear
when transporting, moving and installing the boiler.
When working on the pellet grate, cleaning turbulators, and pellet delivery systems, hands
or arms could be injured. Turn off the main power switch when working on these components.