EUROHEAT
DISTRIBUTORS (H.B.S) LTD. Dec 2004
E & OE Instructions Part number IN1084 Ed D
4
FB80 Gas Insert Conventional Flue Technical Data
FB80 Gas Conventional flue
739
690
465
615
435
100
80
630
Gas
connection
8 mm
70
Heat Vent Outlet
Gas
Mbar
Main Jet
mm
Pilot Jet
Ø
Ø
mm
Burner
pressure
Low
Burner
Pressure
G20H
Nat Gas
20
4 x 1.17
0.95
m
³/h
19mbar
0.38
m
³/h
2.9mbar
99-03
1.7
G31
LPG
37
4 x 0.75 0.68kg/h 36.4mbar 0.33kg/h
8.9mbar
98-24
1.2
Gas
Pressure
Maximum output
Minimum output
Hourly
flow
Hourly
flow
Low Burn
By-pass
Jet
Model Number 499944011
Heat Output
Natural Gas
8kW (27,300BTU)
LP Gas
6.8kW (23,200BTU)
Gas Input
Natural Gas
9.2kW (31,400BTU)
LP Gas
7.9kW (26,900BTU)
Heat Control Mertik Gas Valve.
Manual Control or Remote
control option.
Sit Gas Valve (eurosit 630)
Manual and Thermostatic
Fuel Types Natural Gas or LPG
(specify at time of order)
Ignition Type Mertik Gas Valve Piezo
Sit Gas Valve Battery
Pilot Flame
Yes
Flame Failure
Yes
Fuel effect
Coal
Fuel outlet Top 125mm (5”) Internal
Diameter
Warranty Standard 1 Year