EUROHEAT
DISTRIBUTORS (H.B.S) LTD. Dec 2004
E & OE Instructions Part number IN1084 Ed D
25
Lighting
For full operating instructions see operation manual.
Turn the on/off knob, smaller right hand knob, slightly counter-clockwise towards the ignition position
until the control knob stops turning, press it down and hold for 5 seconds to alow the gas to the pilot
light.
After 5 seconds turn the control to the pilot position with the knob still depressed. There will be an
audible click as the Piezo spark is generated. Hold down the control knob for 30 seconds if the pilot
has lit, if it has not lit then repeat the pilot lighting procedure to maximum of 6 attempts. If after 6
attempts the pilot has not ignited leave the appliance for 2 minutes before attempting again. (This
assumes the system has been purged)
Once the pilot has been established, let out the control knob and turn it anticlockwise to the “ON”
position.
Manual Control
Turn the larger left hand control anti clockwise to increase, clockwise to decrease the desired heat
output.
5
6
2
1
3
4
PILOT
O
FF
IG
N
O
N
Manual Control.
The manual control will
set the output from the
burner, varying from
maximum to minimum
output or any setting in
between.
On/Off
Pilot Setting and
Ignition Control
Mertik Maxitrol GV34 Gas Valve